PD6830X Explosion-Proof Modbus Scanners
Instruction Manual
45
System (
SYSTEM
)
The system function is used to set the real time
clock, set daily data log times, enable/disable the
backlight, access analog output controls used in
troubleshooting, store, restore, and backup restore
feature, enable/disable the battery power alert sym-
bol on the display, and review basic system identifi-
cation information.
Set Real Time Clock (
SETTIME
)
The real time clock is used to trigger data log events,
and is recorded at every logged data point. The
Set
Time
menu displays the date and time.
Figure 10. Real Time Clock Display Example –
Decimal Model
Figure 11. Real Time Clock Display Example –
Feet & Inches Model
The above display examples show the date to be
June 27, 2013; at 14 hours, 32 minutes, and
36 seconds.
The year, month, day, hour, and minute may all be set
by the user. The real time clock will need to be reset if
external power and battery power are lost.
To program the time, select the time or date
component to be programmed, and press
Enter
. To
enter the time or date as a numeric value, see
on page
Changing the time (hours and minutes) will reset the
second clock to 0.