Model 3710 Plasma Control Console
Operator’s
Manual
_____________________________________________________________________________________________________________________
Issued: 03/11
Page
32
5.
Attach power cable P/N
5005296
to console POWDER FEEDER #
1 POWER connector, then to the # 1 Powder Feeder.
6.
If using a second Powder Feeder, attach second control cable to
console POWDER FEEDER # 2 POWER connector, then to the #
2 Powder Feeder.
F.
Heat Exchanger/Pump Connections
1.
Attach control cable # 12 (P/N
5005265
) to console J2 connector,
then to heat exchanger or pump.
G.
Power Source and High Frequency Unit Connections
Verify that the Power Supply and the High Frequency Unit is locked out
from any input power source.
1.
A. For PS-1000 Power Supply only, attach cable P/N
5008637
to
the console PS100 connector, then to the Junction Box.
B.
For HPS-100 Power Supply only, attach cable P/N
610402-25
to
the console PS100 connector, then to the HPS-100 Power
Supply.
2. Attach cable # 9 (P/N
5005224
) to console HIGH FREQUENCY
POWER connector, then to the High Frequency Unit.
3. Attach cable # 10 (P/N
5005222
) to console HIGH FREQUENCY
CURRENT connector, then to the High Frequency Unit.
4. Attach cable # 11 (P/N
5005272)
to console HIGH FREQUENCY
VOLTAGE connector, then to the voltage sense connections on the
High Frequency Unit.
5. For PS-1000 Power Supply only, attach cable P/N
5008632
to the PS-
1000 Power Supply and then to the Junction Box.
PS-1000
V
HPS-100