After confirming the number entered by pressing OK, enter the
channel number, increasing or decreasing its value using the up
and down arrow buttons.
If the receiver is configured in free mode, the number of the
relay to be activated upon receipt of the emitted channel must
be selected.
Then, you will need to provide the number of transmitters to be
programmed knowing that the previous number is for the
group's first transmitter and that the subsequent numbers shall
automatically be incremented.
The relay number and the number of transmitters to be
programmed are selected using the up and down arrow buttons.
Once the correct value is displayed, confirm it by pressing OK.
The receiver memory will then be automatically populated. The
GT+ will return to the mode in which it waits for input of the next
transmitter number. Press the left arrow button to exit the
manual programming mode.
If a receiver is in default mode, the first transmitter number and
the number of transmitters to be created will be automatically
copied to the receiver memory after confirmation and the GT+
will return to the mode in which it waits for input of the next
transmitter number.
“Config. relays” Submenu:
This submenu allows the receiver relay commands to be configured.
The up and down arrow buttons may be used to move through the relay
output numbers to be configured.
The type of relay command may be edited by pressing the right arrow
button. It may be configured in monostable mode, bistable mode and
time-out mode.
In time-out mode, the time-out value for the relay command may be
increased or decreased using the up and down arrow buttons.
Incrementation occurs in 0.1 second intervals. The user may press and
hold the button for automatic incrementation.
Values are recorded in the receiver memory by pressing the OK button.
"Enabled groups" Submenu:
This submenu allows the enabled groups of the receiver to be edited.
Value of enabled group must be between 1 and 255.
The cursor is placed under the figure which can then be edited using the
up and down arrow buttons. The cursor may be moved using the left
and right arrow buttons.
The number entered is confirmed and the system moves on to the next
enabled group by pressing OK.
“Password” Submenu:
This submenu allows the access to the receiver memory to be password
protected. Once a password has been confirmed in a receiver, the
password must be entered before any change is applied to a memory
parameter or item.
Password must be between 1 and 65535.
"00000" will cancel the password.
The cursor is placed under the figure which can then be edited using the
up and down arrow buttons. The cursor may be moved using the left
and right arrow buttons.
Passcode is confirmed by pressing OK twice.
Code: 00000100
Nr. codes:1
Password: 00000
(new)
^
Enabled groups
>
Password
Group: 000
^
>Enabled groups
Password
Relay 1:
Temp. 0.1s
Relay 1:
Bistable
Relay 1:
Monostable
>
Config. relays
Enabled groups
Code: 00000100
Chan.:1 Relay:1
Code: 00000100
Chan.: 1