9116QF01
LERBAKKEN 10, 8410 ROENDE DENMARK
Revision date:
2010-02-12
Version Revision
V5 R0
Prepared by:
PB
Page:
3/4
Uo, Voc
28 V
IIC or A,B
80 nF
4 mH 54
μ
H/
Ω
Io, Isc
93 mA IIB or C,E,F
640 nF
16 mH 218
μ
H/
Ω
Po
650 mW IIA or D,G
2.1
μ
F
32 mH 436
μ
H/
Ω
Uo, Voc
21.4 V IIC or A,B
0.16
μ
F
4 mH 54
μ
H/
Ω
Io, Isc
93 mA IIB or C,E,F
1.13
μ
F
16 mH 218
μ
H/
Ω
Po
650 mW IIA or D,G
4.15
μ
F
32 mH 436
μ
H/
Ω
Module 9116B2
Terminal 52-54
Group
Co
Lo
Lo/Ro
Lo/Ro
Module 9116B1
Term. 54-52; 51-52
Group
Co
Lo
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
2
μ
H
Terminal 54-52
Module 9116B 1/2
T
+
-
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
Unclassified Location
or
Hazardous Classified Location
Class I, Division 2 Group A,B,C,D T4
Class I, Zone 2, Group IIC, IIB, IIA T4
Hazardous Classified Location
Class I / II / III, Division 1, Group A,B,C,D,E,F,G
Class I Zone 0 / 1 / 2 Group IIC, IIB, IIA or
Class I Zone 20 / 21
4-20 mA
Loop-powered
transmitter
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253 V max. 400 Hz
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max: 125 VAC / 110 VDC
Power max:
62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC
Zone 2 installation:
Voltage max: 32 VAC/ 32 VDC
Power max:
16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max: 250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30 VDC
Power max:
64 VA / 60 W
Current max: 2 A AC / 2 ADC
-20 ºC
≤
Ta
≤
+60ºC
PENDING
Содержание 9116
Страница 34: ...32 9116 Product Version 9116 001 ...
Страница 66: ...64 9116 Product Version 9116 001 ...
Страница 98: ...96 9116 Product Version 9116 001 ...