Chapter 5 Function parameter
29
Ch
ap
ter
5
49
Deceleration DC
braking
If the terminal is valid, firstly the inverter decelerates to the
initial frequency of stop DC braking, and then switches
directly to DC braking status.
50
Clear current running
time
If the terminal is valid, the inverter's current running time is
cleared,
55
F1.10 Terminal command mode
0:Two-wire type 1;1:Two-wire type 2;
2:Three-wire type 1;
3:Three-wire type 2
0
★
56
F1.11
Terminal UP / DOWN
change rate
0.001Hz/s to 65.535Hz/s
1.000Hz/s
☆
57
F1.12 Minimum input for AIC1 0.00V to F1.14
0.30V
☆
58
F1.13
F1.12 corresponding
setting
-100.0% to +100.0%
0.0%
☆
59
F1.14 Maximum input for AIC1 F1.12 to +10.00V
10.00V
☆
60
F1.15
F1.14 corresponding
setting
-100.0% to +100.0%
100.0%
☆
61
F1.16 Minimum input for AIC2 0.00V to F1.18
0.00V
☆
62
F1.17
F1.16 Corresponding to
the set
-100.0% to +100.0%
0.0%
☆
63
F1.18 AIC2 max. Input
F1.16 to +10.00V
10.00V
☆
64
F1.19
F1.18 corresponding to
the set
-100.0% to +100.0%
100.0%
☆
65
F1.23
F1.22 corresponding to
the set
-100.0% to +100.0%
100.0%
☆
66
F1.24 AI curve selection
Units digit:AI1 curve selection
Tens digit: AI2 curve selection
321
☆
67
F1.25 AI input setting selection
Units digit: AI1 lower than minimum
input setting selection;
0: Correspond to minumum input
setting;1:0.0%;
Tens digit: AI2 lower than minimum
input setting selection;
000
☆
68
F1.30 DI filter time
0.000s to 1.000s
0.010s
☆
69
F1.31 AI1 filter time
0.00s to 10.00s
0.10s
☆
70
F1.32 AI2 filter time
0.00s to 10.00s
0.10s
☆
71
F1.35
DI terminal mode
selection 1
Units digit: DI1
0:High level active ;1:Low level active
Tens digit:DI2(Same as the units digit)
00000
★
72
F1.37 DI1 delaytime
0.0s to 3600.0s
0.0s
★
73
F1.38 DI2 delaytime
0.0s to 3600.0s
0.0s
★
74
F1.39 DI3 delaytime
0.0s to 3600.0s
0.0s
★
75
F1.40
Definethe inputterminal
repeat
0:Unrepeatable; 1:Repeatable
0
★
76
F1.42 Keyboardpotentiometer 0 to 100.00%
0.50%
☆