TC310VP Instruction Manual

Powtier Controls Limited

ORDERING INFORMATION

You are welcome to order by description or code.

310VP-

-

-

-

-

- 00

INPUT......................................................................:

:

:

:

:

:

SCALE................................................................................:

:

:

:

:

SUPPLY VOLTAGE......................................................................:

:

:

:

VALVE POSITIONER OUTPUT............................................................:

:

:

OPTION...........................................................................................................:

:

END OF CODE..........................................................................................................:

INPUT

Iron-Constantan (J) BS -50 to 500.....................1
Iron-Constantan (J) DIN -50 to 500...................30
Chromel Alumel (K) -50 to 500...........................2
Chromel Alumel (K) 0 to 999..............................3
Resistance Thermometer (PT100) -50 to 200. . .4
(Other range options on application)

SCALE

Degree Celsius.............................................................C
Degree Fahrenheit........................................................F

SUPPLY VOLTAGE

115/230V +/-15% 50/60Hz......................................................1
100/200V +10% -15% 50/60Hz..............................................2

VALVE POSITIONER OUTPUT

Control 24Vac motor........................................................................48
Control 120Vac or 240Vac motor....................................................49

OPTIONS

No option...................................................................................................01
Low deviation alarm...................................................................................21
High deviation alarm..................................................................................22
Band deviation alarm.................................................................................23
Two term PD Control.................................................................................31
On-off control.............................................................................................32
Downscale Thermocouple break protection..............................................61
Retransmission signal 0-5V 5mA max.)....................................................63

END OF CODE.........................................................................................................00

Please consult Sales office for other possible options and scales.

ORDER EXAMPLE:
1. A TC310VP with J-type thermocouple input (BS standard), scaled -50 to 500 °C, operating at 230V, valve
positioner control a motor having a supply voltage of 24Vac with high deviation alarm as option will have the
code:- 310VP-1-C-1-48-22-00. 

SUPPLIER INFORMATION

Powtier Controls Limited
Unit 4, Parkland Business Centre
Chartwell Road, Lancing
West Sussex BN15 8UE England
Tel: +44(0)1903 750800
Fax: +44(0)1903 750678

Email: 

[email protected]

14 March 1995

- 8 -

310VPIM

Issue 2.0

Содержание Tactical 310

Страница 1: ...OLLER WITH VALVE POSITIONER OUTPUT INSTRUCTION MANUAL CONTENTS DESCRIPTION 2 INSTALLATION 2 CONNECTIONS 3 CONTROL ADJUSTMENTS 4 TUNING 5 ALARM SETTING 6 TECHNICAL SPECIFICATION 7 ORDERING INFORMATION...

Страница 2: ...etpoint changeover switch on the front panel Setpoint adjustment is made by turning the setpoint thumbwheel which is concealed behind the door on the front panel Wiring connections are made at the bac...

Страница 3: ...TC310VP Instruction Manual Powtier Controls Limited CONNECTIONS Typical TC310VP wiring Schematic Terminal connection diagram 14 March 1995 3 310VPIM Issue 2 0...

Страница 4: ...nual Reset optional can be used to remove the steady state error inherent in PD control P10 Not used P11 Not used P12 High Low Band Alarm optional only one type on any instrument can be used to give a...

Страница 5: ...to table 2 8 Progressively reset P13 P14 as far clockwise as possible without the introduction of system hunting Table 1 Switch settings for integral and derivative time constant SID ti td SID ti td 1...

Страница 6: ...just comes on The high alarm will now operate at t degrees above any chosen set point temperature 2 STEPS IN SETTING A LOW ALARM LEVEL 2 1 Ensure that the sensor input to the controller is at a steady...

Страница 7: ...span Derivative time td 0 5 to 5 minutes Manual reset PD control only 0 to 50 output power at span ON OFF control option Hysteretic 0 5 of span ALARMS OUTPUTS option Relay Normally energised and de en...

Страница 8: ...r 49 OPTIONS No option 01 Low deviation alarm 21 High deviation alarm 22 Band deviation alarm 23 Two term PD Control 31 On off control 32 Downscale Thermocouple break protection 61 Retransmission sign...

Отзывы: