3.5 Testing And Checking
Make sure the notices included in 1.1 General safety precaution “WARNINGS” has been carefully observed.
● Release the gearmotor with the proper release key.
● Make sure the gate can be moved manually during opening and closing phases with a force of max.
390N (40 kg approx.)
● Lock the gearmotor.
● Using the Key selector switch, push button device or the radio transmitter, test the opening, closing and
stopping of the gate and make sure that the gate is in the intended direction.
● Check the devices one by one (photocells, flashing light, key selector, etc.) and confirm the control unit
recognizes each device.
Gate Status
Closed
Open
Stop during moving
Closing
Opening
Photocell 2
Stop opening
No effect
Stop opening
No effect
Closes the leaf
Photocell 1
No effect
Open
No effect
Reloads automatic closing time
Reloads automatic closing time
Photocell 1/ Photocell 2
Stop opening
Locks and, on release, reverses to open
Locks and, on release, continues opening
Logic F3-1
The reactions of the photocells when detecting obstacles
Gate Status
Closed
Open
Stop during moving
Closing
Opening
Safety Edge
Stop opening
Stop opening/ closing
Reverses to open for 2 seconds
Reverses to close for 2 seconds
Photocell 1
No effect
Reloads automatic closing time
Open
No effect
Reloads automatic closing time
Logic F3-2
The reactions of the safety edge/ photocell when detecting obstacles
Gate Status
Closed
Open
Stop during moving
Closing
Opening
Loop Detector
Open
Open
Open
Open
Photocell 1
No effect
Reloads automatic closing time
Open
No effect
Reloads automatic closing time
Logic F3-3
The reactions of the loop detector/ photocell when detecting obstacles
● F3 function settings:
●
The position of safety devices:
Photocell 1 / Photocell 2
Photocell
Safety Edge
Photocell 1
or
Photocell 1
Loop Detector
Photocell 2
INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL
9