background image

3.6 SW2/SW6 Setting:

ON

OFF

ON

OFF

PH2

Ph2

Stop

D

C

SW6

SW2

1

2

3

4

5

6

SW6 Dip Switch

Dip Switch

1

2

3

Setting

ON

OFF

ON

OFF

ON

OFF

Device

Ph1

Ph2

Stop

Description

Ph1 NOT connected

PH2 connected

Ph2 NOT connected

Ph2 connected

Stop NOT connected

Stop connected

10

 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL

2 channel transmitter

4 channel transmitter
(Optional)

Button A(left): Open-Stop-Close-Stop
Button B(right): External Device
Button A(left): Open-Stop-Close-Stop
Button B(right): External Device

Button A(left): Open-Stop-Close-Stop
Button B(right): Pedestrian Mode
Button A(left): Open-Stop-Close-Stop
Button B(right): Pedestrian Mode

Button C(up): 
External Device

Button D(down): 
No Function

Button C(up): 
Pedestrian Mode

Button D(down): 
No Function

Transmitter 

                                  SW2 Dip Switch on 

                          SW2 Dip Switch off

SW6 Dip Switch 4 on, Dip Switch 5 off           SW6 Dip Switch 4 on, Dip Switch 5 off

Button C(up): 
No Function

Button D(down): 
External Device

Button C(up): 
No Function

Button D(down): 
Pedestrian Mode

SW6 Dip Switch 4 off, Dip Switch 5 on           SW6 Dip Switch 4 , Dip Switch 5 on

LED1 Photocells
LED2 Photocells
LED3 RF Learning

LED1 will be on when the first pair of the photocells are activated.
LED2 will be on when the second pair of the photocells are activated.
LED3 will be on when RF-learn button is pressed.

LED Indication                                                                     Descriptions

3.6.1 Recognition of LED

Содержание PL500

Страница 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL500 24V DC MOTOR ...

Страница 2: ...product has been tasted for CE marking according to the following European Directives 2006 42 EC Machinery Directive Comply with the following Standards EN 301489 1 V1 8 1 2008 EN 301489 3 V1 4 1 2002 EN 300220 1 V2 1 1 2006 EN 300220 2 V2 1 2 2007 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 103 2003 EN 62233 2008 EN 12445 2001 EN 12453 2001 And also declare that the mach...

Страница 3: ...g Reset Process and LED Display 3 4 Programmable Function Settings 3 5 Testing and Checking 3 6 SW2 SW6 Setting 3 6 1 Recognition of LED 4 Technical Characteriestics 4 1 Technical Data Sheet of Series 4 2 PH 1 Photocell Data Sheet 4 3 PR 1 Transmitter Data Sheet 4 4 PF 1 Flashing Light Data Sheet 4 5 PRB 1 External Receiver Box Data Sheet 5 Additional Information 5 1 Wire Connection of PH 1 Photoc...

Страница 4: ... the gates work properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated acci...

Страница 5: ... photo sensor 4 Flashing light a Operation gear b Limit switch device c 24Vdc motor d Back up batteries Optional e Release device f Control panel g Terminals of devices 2 Installation 3 4 2 3 e f g a b c d 2 2 Description of Device INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 3 1 ...

Страница 6: ...2 3 Dimension of Device 2 4 Installation of Motor Gear and Gear Rack 100 25 50 25 1 2m 4 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL ...

Страница 7: ...ure as below Step1 Push the lid of release chamber and move rightward Step2 Insert the key and turn counterclockwise to unlock the device Step3 Turn counter clockwise of the bar to release the motor To restore the automation simply reverse the above procedure Step1 Step2 Step3 NO OK DX SX INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 5 ...

Страница 8: ... 11 PPB 1 PPB 1 PKS 1 PKS 1 SW1 SW3 SW4 SW5 3 4 PF 1 PF 1 AC INPUT 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 AC INPUT 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 6 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL LED1 Photocells LED2 Photocells LED3 RF Learn AC INPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 C lo s e S to p G N D P b P h P h 2 P h 1 G N D E X T E X T G N D...

Страница 9: ...LED2 LED3 ON OFF Press 1 3 Sec Press 3 Sec Push 1 2 3 4 5 6 1 LED1 LED2 LED3 ON OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 LED1 LED2 LED3 ON OFF Push 3 seconds 1 2 LED Display Programmable Functions LED Display Programmable Functions N L The PL500 system learning is not done LEA Enter learning mode and then wait for learning instructions CLR Reset Factory Setting ARN The system learning is in progress The...

Страница 10: ...ght 2 The factory setting is F5 4 3 The motor force value F5 1 2A F5 6 7A F5 2 3A F5 7 8A F5 3 4A F5 8 10A F5 4 5A F5 9 13A F5 5 6A 4 As over current setting 1 The function can adjust the time of opening partially 2 The factory setting is F6 1 3 Press button B on the remote to operate the pedestrian mode 1 The factory setting is F7 0 1 The factory setting is F8 1 1 The factory setting is F9 2 1 Th...

Страница 11: ...tomatic closing time Photocell 1 Photocell 2 Stop opening Locks and on release reverses to open Locks and on release continues opening Logic F3 1 The reactions of the photocells when detecting obstacles Gate Status Closed Open Stop during moving Closing Opening Safety Edge Stop opening Stop opening closing Reverses to open for 2 seconds Reverses to close for 2 seconds Photocell 1 No effect Reloads...

Страница 12: ...ode Button A left Open Stop Close Stop Button B right Pedestrian Mode Button C up External Device Button D down No Function Button C up Pedestrian Mode Button D down No Function Transmitter SW2 Dip Switch on SW2 Dip Switch off SW6 Dip Switch 4 on Dip Switch 5 off SW6 Dip Switch 4 on Dip Switch 5 off Button C up No Function Button D down External Device Button C up No Function Button D down Pedestr...

Страница 13: ...L W H Output 1 Output 2 4 5 PRB 1 External Receiver Box Data Sheet 4 2 PH 2 Photocell Data Sheet 4 Technical Characteristics Detection type Operating distance Response time Input voltage Operating Temperature Protection class Dimension Through beam 25 meters 100ms AC DC 12 24V 20 60 IP54 96mm 45mm 43mm 4 1 Techanical Data Sheet Of Series Worm Gear 5500N 5000N 3800 RPM 60W 24 Vdc 3A 500kg 6 Meters ...

Страница 14: ...receiver with the terminals Ph GND and Ph1 on the P600B PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge Detection Method Sensing Range Input Voltage Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Max Water Proof Through Beam 25M AC DC 12 24V 100MS IR LED Red LED RX ON When Beam is Broken Green TX ON 96 45 43mm Rela...

Страница 15: ...press and hold Learn Button for 1 second the LED light should be ON If the LED does not respond please check the cable connection again c Press and hold Button C on the remote for 1 second after the LED is ON The remote completed the memorizing process when LED light turns OFF 3 Device Testing Remote Memorization a Orange cable Signal 1 connect to terminal 10 Pb on the control board b Blue cable G...

Страница 16: ...ech Automation Inc Output 1 operation LED Light Output 2 operation Single gate operation for Powertech gate openers Dual gate operation for Powertech gate openers 4 Memory Erasing Please refer to figure 5 2 1 5 4 Channel Transmitter Operation Figure 5 2 1 A B C D 34100 095 B ...