background image

1. Situation:

In order to use one 4 channel remote to operate with additional device besides the original gate automation system. 
Install a receiver box to connect with the 2nd device (such as another Powertech Slider) 
or the 3rd device (Such as garage automation system) 

Original gate automation: Using Button A & B (Pedestrian Mode) on the remote to control gate opener
2nd device: Install an external receiver box, connect output 1 to the 2nd device (such as another Slider, shown as 
below) use button C on the same remote to control the 2nd device
3rd device: install an external receiver box, connect the output 2 to the 3rd device (such as garage door), use the 
Button D now to operate.

2. Wire Connection:

a. After connect all necessary cables properly , press   
    Test Button to exam if the output 1 is working, the  
    gate opener should operate.
 b. If Output 1 is functional, press and hold Learn Button 
     for 1 second, the LED light should be “ON”
    * If the LED does not respond, please check the  
      cable connection again
c. Press and hold Button C on the remote for 1 second 
    after the LED is “ON”. The remote completed the 
    memorizing  process when LED light turns “OFF”

3. Device Testing & Remote Memorization

a. Orange cable (Signal 1) connect to terminal 10 (Pb) on the control board
b. Blue cable (GND) connect to terminal 11 (GND) on the control board
c. Red cable (12V/24V ac/dc) connect to terminal 9 (Ph+) on the control board
d. Black cable (GND) connect to terminal 11 (GND) on the control board

PRB-1 Receiver 

5.2 Wire Connection and Setting of PRB-1 External Reciever Box

 

Orange

Blue

Yellow

Green

Red

Black

-Signal 1

-GND

-Signal 2

-GND

-12V/24V

-GND

Output 1 (Normally Open Relay)

Output 2 (Normally Open Relay)

12V - 24V AC/DC

RB1 Receiver Box

Orange

Blue

Yellow

Green

Red

Black

-Signal 1

-GND

-Signal 2

-GND

-12V/24V

-GND

9

10

11

GND

Pb

Ph+

 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL

13

LED Light

Learn Button

Test Button

Output 1

Invalid Button

Invalid Button

Содержание PL500

Страница 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL500 24V DC MOTOR ...

Страница 2: ...product has been tasted for CE marking according to the following European Directives 2006 42 EC Machinery Directive Comply with the following Standards EN 301489 1 V1 8 1 2008 EN 301489 3 V1 4 1 2002 EN 300220 1 V2 1 1 2006 EN 300220 2 V2 1 2 2007 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 103 2003 EN 62233 2008 EN 12445 2001 EN 12453 2001 And also declare that the mach...

Страница 3: ...g Reset Process and LED Display 3 4 Programmable Function Settings 3 5 Testing and Checking 3 6 SW2 SW6 Setting 3 6 1 Recognition of LED 4 Technical Characteriestics 4 1 Technical Data Sheet of Series 4 2 PH 1 Photocell Data Sheet 4 3 PR 1 Transmitter Data Sheet 4 4 PF 1 Flashing Light Data Sheet 4 5 PRB 1 External Receiver Box Data Sheet 5 Additional Information 5 1 Wire Connection of PH 1 Photoc...

Страница 4: ... the gates work properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated acci...

Страница 5: ... photo sensor 4 Flashing light a Operation gear b Limit switch device c 24Vdc motor d Back up batteries Optional e Release device f Control panel g Terminals of devices 2 Installation 3 4 2 3 e f g a b c d 2 2 Description of Device INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 3 1 ...

Страница 6: ...2 3 Dimension of Device 2 4 Installation of Motor Gear and Gear Rack 100 25 50 25 1 2m 4 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL ...

Страница 7: ...ure as below Step1 Push the lid of release chamber and move rightward Step2 Insert the key and turn counterclockwise to unlock the device Step3 Turn counter clockwise of the bar to release the motor To restore the automation simply reverse the above procedure Step1 Step2 Step3 NO OK DX SX INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL 5 ...

Страница 8: ... 11 PPB 1 PPB 1 PKS 1 PKS 1 SW1 SW3 SW4 SW5 3 4 PF 1 PF 1 AC INPUT 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 AC INPUT 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 6 INSTRUCTIONS PL500 SLIDING GATE OPENER USER MANUAL LED1 Photocells LED2 Photocells LED3 RF Learn AC INPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 C lo s e S to p G N D P b P h P h 2 P h 1 G N D E X T E X T G N D...

Страница 9: ...LED2 LED3 ON OFF Press 1 3 Sec Press 3 Sec Push 1 2 3 4 5 6 1 LED1 LED2 LED3 ON OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 LED1 LED2 LED3 ON OFF Push 3 seconds 1 2 LED Display Programmable Functions LED Display Programmable Functions N L The PL500 system learning is not done LEA Enter learning mode and then wait for learning instructions CLR Reset Factory Setting ARN The system learning is in progress The...

Страница 10: ...ght 2 The factory setting is F5 4 3 The motor force value F5 1 2A F5 6 7A F5 2 3A F5 7 8A F5 3 4A F5 8 10A F5 4 5A F5 9 13A F5 5 6A 4 As over current setting 1 The function can adjust the time of opening partially 2 The factory setting is F6 1 3 Press button B on the remote to operate the pedestrian mode 1 The factory setting is F7 0 1 The factory setting is F8 1 1 The factory setting is F9 2 1 Th...

Страница 11: ...tomatic closing time Photocell 1 Photocell 2 Stop opening Locks and on release reverses to open Locks and on release continues opening Logic F3 1 The reactions of the photocells when detecting obstacles Gate Status Closed Open Stop during moving Closing Opening Safety Edge Stop opening Stop opening closing Reverses to open for 2 seconds Reverses to close for 2 seconds Photocell 1 No effect Reloads...

Страница 12: ...ode Button A left Open Stop Close Stop Button B right Pedestrian Mode Button C up External Device Button D down No Function Button C up Pedestrian Mode Button D down No Function Transmitter SW2 Dip Switch on SW2 Dip Switch off SW6 Dip Switch 4 on Dip Switch 5 off SW6 Dip Switch 4 on Dip Switch 5 off Button C up No Function Button D down External Device Button C up No Function Button D down Pedestr...

Страница 13: ...L W H Output 1 Output 2 4 5 PRB 1 External Receiver Box Data Sheet 4 2 PH 2 Photocell Data Sheet 4 Technical Characteristics Detection type Operating distance Response time Input voltage Operating Temperature Protection class Dimension Through beam 25 meters 100ms AC DC 12 24V 20 60 IP54 96mm 45mm 43mm 4 1 Techanical Data Sheet Of Series Worm Gear 5500N 5000N 3800 RPM 60W 24 Vdc 3A 500kg 6 Meters ...

Страница 14: ...receiver with the terminals Ph GND and Ph1 on the P600B PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge Detection Method Sensing Range Input Voltage Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Max Water Proof Through Beam 25M AC DC 12 24V 100MS IR LED Red LED RX ON When Beam is Broken Green TX ON 96 45 43mm Rela...

Страница 15: ...press and hold Learn Button for 1 second the LED light should be ON If the LED does not respond please check the cable connection again c Press and hold Button C on the remote for 1 second after the LED is ON The remote completed the memorizing process when LED light turns OFF 3 Device Testing Remote Memorization a Orange cable Signal 1 connect to terminal 10 Pb on the control board b Blue cable G...

Страница 16: ...ech Automation Inc Output 1 operation LED Light Output 2 operation Single gate operation for Powertech gate openers Dual gate operation for Powertech gate openers 4 Memory Erasing Please refer to figure 5 2 1 5 4 Channel Transmitter Operation Figure 5 2 1 A B C D 34100 095 B ...