background image

ARTICULATED ARM OPENERS

FOR RESIDENTIAL

USER MANUAL

24V DC GEAR MOTOR

PA250 USER MANUAL

Содержание PA250

Страница 1: ...ARTICULATED ARM OPENERS FOR RESIDENTIAL USER MANUAL 24V DC GEAR MOTOR PA250 USER MANUAL ...

Страница 2: ...the contents marked by the symbol Be aware of the hazards that may exist in the procedures of installation and operation of the gate automated system Besides the installation must be carried out in conformity with local standards and regulations If the system is correctly installed and used following all the standards and regulations it will ensure a high degree of safety Make sure that the gates ...

Страница 3: ...arting the installation please make sure that the gate moves freely and that 1 Hinges are properly positioned and greased 2 No any obstacle in the moving area 3 No frictions between two gate leafs or and on the ground while moving 4 Installation reference to open the gate with 90 degree please refer the data table below A Distance between the gate hinge and the wall bracket B Distance between the ...

Страница 4: ... pcs 4 pcs 4 pcs 1 pce 2 3 4 5 6 7 8 13 12 11 10 9 1 1 Refer to the Dimension Chart to choose the correct dimensions of the motors and position to be installed 2 Check if the mounting surface of the brackets to be installed is smooth vertical and rigid 3 Arrange the cables for power supply cable of the motors 4 Motor installation and setting for mechanical stopper in opened and closed position 2 P...

Страница 5: ...ter on limit switch aligned with the pointer on the curved arm Red points shown on the figure below indicate the pointers 6 Opened position adjustment 5 1 Adjust the gate to full opened position and after the position decided fixed with corresponding mechanical stopper 5 2 Adjust the gate to full opened position and after the position decided make the pointer on the electromechanical limit switch ...

Страница 6: ...d 2 on the transmitter with the terminals GND and PhVcc on the PC190 PCB RX Connect terminals 1 2 and 4 on the receiver with the terminals GND PhVcc and Ph1 Ph2 on the PC190 PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge Detection Method Sensing Range Input Voltage Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Ma...

Страница 7: ...ARTICULATED ARM OPENERS USER MANUAL 5 Figure 1 3 SKey Ph2 Ph1 PhVcc PhVcc DKey GND GND 19 20 21 22 23 24 25 26 1 2 3 4 5 COM NC NO 1 2 RX1 TX1 1 2 3 4 5 COM NC NO 1 2 RX2 TX2 ...

Страница 8: ...icity AC OUT connect the power of gate opener and connect the transformer 5V CABLE connect 3 pins white socket of control board Please make sure the switch of Green Box is off before proceeding the system learning and installation of device Wait for the system learning and installation of device to be completed power on the Green Box Gate opener will enter power saving mode without receiving any i...

Страница 9: ...h Transformer Antenna Green Box LED Display Blue LED RF Learning LED2 Push button or Key selector LED3 Photocell 1 LED 4 Photocell 2 UP SET SET DOWN RF LEARN RF LEARN LED2 LED4 LED3 11 Lit Lit Lat Lat M1 M1 M2 M2 5V S1 S2 GND Lmt1 Lmt2 GND Lmt3 Lmt4 GND GND Ph1 Ph2 PhVcc PhVcc GND DKey SKey 26 24 25 23 21 22 19 20 18 16 17 15 13 14 11 10 12 9 8 6 7 5 3 4 1 2 ...

Страница 10: ...S2 5V ANT GND DKey GND GND GND GND Lmt1 GND PC190 PCB1 40121 377 A1 T4 SW3 UP J1 Q17 R113 R112 R111 R110 R108 R107 R106 R105 R104 R103 R102 J5 SW1 RF LEARN RF1 MOV1 K5 K3 K2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 M1 Limit1 Limit2 GND M1 Motor1 Power Limit Switch M2 Li...

Страница 11: ...D GND GND Lmt1 GND PC190 PCB1 40121 377 A1 T4 SW3 UP J1 Q17 R113 R112 R111 R110 R108 R107 R106 R105 R104 R103 R102 J5 SW1 RF LEARN RF1 MOV1 K5 K3 K2 K1 J4 J3 J7 J2 F1 DB1 J8 SW4 SET SW5 DOWN NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 M1 Limit1 Limit2 GND M1 Motor1 Power Limit Switch M2 M1 Lat Lit Lmt4 Lmt3 Lmt2 L...

Страница 12: ...NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED2 LED3 LED4 2 2 LED Indication Step1 Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly If only one gate is installed the motor wires have to be connected to M1 terminals Step2 Set the function F2 1 for dual gate learning or set the function F2 2 for singl...

Страница 13: ...System learning fails and needs to be learned again when an unpredictable interruption occurs B Once the system learning is completed there is no need to proceed with the learning process again when there isa power failure C The slave gate opens 3 seconds after the master gate opens and the master gate closes 3 seconds after the slave gate closes D While using limit switch mode please make sure th...

Страница 14: ...with the release key and move the gate to the middle so that it is free to move in both opening and closing directions then lock the gearmotor 2 Perform the gate opening and closing several times and make sure the gates reaches the limit switch at least 2 3 centimeters before the mechanical stop 3 1 Function Of The Led Display 3 Function Setting LED Display Programmable Functions N L The system le...

Страница 15: ...load automatic closing time Open No effect Position of Gate When safety devices are activated 3 F9 3 Type of Safety Device FULLY CLOSED FULLY OPENED STOP DURING MOVING CLOSING OPENING Safety Device2 Opening Device Open Open Open No effect Reload automatic closing time Safety Device1 Photocell CLOSE No effect Reload automatic closing time Open No effect Position of Gate When safety devices are acti...

Страница 16: ... option 3 Continually press the Down button until you search the function 0 of F1 as the right hand side picture F1 0 is set completely If you would like to set one of functions 0 8 as the second option please press the UP or Down button to adjust it 4 If you would continue setting up the next functions please press SET to return the first option like F1 or F2 or F3 or F8 For example after complet...

Страница 17: ... F8 3 F8 4 F8 5 F8 6 F8 7 F8 8 F9 1 F9 2 F9 3 F9 4 FA 0 FA 1 FB 0 FB 1 Motor only Motor with Limit Switch Motor with Hall sensor Dual Gate Single Gate 2A 3A 4A 5A 100 Full speed 80 Full speed Function ON Function OFF 70 Full speed 50 Full speed 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec 10 sec Function OFF 3 sec 10 sec 20 sec 40 sec 60 sec 120 sec 180 sec 300 sec Mode 1 Mode 2 Mode 3 Mode 4 F...

Страница 18: ...unction OFF Function ON Function OFF Function ON A Key B Key C Key D Key Function OFF A Key B Key C Key D Key No key to control A Key B Key C Key D Key 1 The factory setting is FC 0 1 The factory setting is FD 0 1 The factory setting is FE 1 1 If the function on the gate will move forword a little before the gate operate for releasing the latch 2 The factory setting is FF 1 1 The factory setting i...

Страница 19: ...e wiring connection of the hall sensor is firm Make sure the connecting terminals of the Antenna is firm Check the dip switch setting of the speed adjustment Check if the wiring connection of the flashing light is correct Change the polarity connection of the positive with the negative of the gear motors 1 Check if the RESET socket is activated 2 Make sure the wiring connection of the gear motors ...

Страница 20: ...nction of the manual release 3 Check the function of photocells or other safety devise 5 2 Technical Feature Model Motor Gear type Nominal thrust Maximum Gate Weight Maximum Gate Length Operating Temperature Dimension Weight PA250 24Vdc motor Electromechanical worm gear 2500N 250 kg per leaf 2 5 meters per leaf 20o C 50o C 256 x 187 x 267mm 6 kg Model Main power supply Back up battery Receiver boa...

Отзывы: