6
b.
Recover when load is reduced: resume normal charging( 30A) when the heat sink
temperature is <70°C.
c.
Stop charging when the heat sink temperature is
≥
90°C; resume charging when the heat
sink temperature is <60°C.
5.
External temperature compensa
tion
function
(only for AGM/STD ba
tt
ery)
a.1.The system will automatically adjust the float voltage according to the ambient temperature.
The external temperature probe is preferred. If the external temperature probe is not connected
(or the external temperature is <-40°C), use (temperature ≥ 20°C± 5°C) by default. 2. The voltage
may vary when the input energy is insufficient to stabilize the energy required for the float
charging.
1. 12V battery charging
temperature ≤0
°C
- -40
°C
14.1
±0.3 VDC
(test external analog resistance430K (-20
°C
))
2. 12V battery charging
temperature: 0
°C
-20
°C
±5
°C
13.8
±0.3 VDC
(test external analog resistance 100K (10
°C
)
3. 12V battery charging
temperature ≥20
°C
±5
°C
13.5
±0.3 VDC
(test external analog resistance 39K (30
°C
)
4. 24V battery floating charge
temperature ≤0
°C
- -40
°C
28.2
± 0.3 VDC
(test external analog resistance 430K (-20
°C
)
5. 24V battery floating charge
temperature 0
°C
-20
°C
±5
°C
27.6
±0.3 VDC
(test external analog resistance 100K (10
°C
)
6. 24V battery floating charge
temperature ≥20
°C
±5
°C
27
±0.3 VDC
(test external analog resistance 39K (30
°C
)
6.
WIFI networking
function
a. The product may integrate WIFI module or not.
b. If the product integrates a WIFI module, you can install the mobile APP, control the load
switch through the APP and view the MPPT charger data in real
ti
me, such as ba
tt
ery
voltage, charging current, etc.
7.
The LCD backlight is turned o
ff
if there is no bu
tt
on opera
tion
in 1 minute; any bu
tt
on
opera
tion
will automa
ti
cally
acti
vate the LCD backlight.
8.
a. USB ba
tt
ery input undervoltage/overvoltage prot
ection
(10.5V/30.5V), ba
tt
ery input
undervoltage/overvoltage recovery (11V/30V);
c.
USB output 2*5V/3A.