background image

10

Maximum PV input power (W) 

12V

 

batt

ery

450W; 24

 V 

battery

900W; 

Maximum MPPT current 

               

30A 

DC output 

 

Battery

 voltage (VDC) 

12//24V 

Battery

 capacity (AH) 

30AH 

Output current (A)

 

30A Max 

Constant voltage charging voltage 

STD:14.4V/28.8V 

       LI:14.5V 
       AGM:14.6V/29.2V 

Load output 

 

Output voltage (VDC) 

12/24V 

Output current (A) 

30A/35A 

USB output

 

 

Output voltage (VDC) 

Number of USB ports 

Maximum output current (A) 

3.4A Max 

Standby current 

Battery

 input 12V 

Separate MPPT charger 

< 60 mA 

MPPT c WIFI module 

< 160 mA 

Protective

 

function

 

 

 

PV/battery

 input high/low voltage 

protection

 

Yes 

PV/battery

 reverse conn

ection

 protec

ti

on

Yes 

Load overcurrent / short circuit protec

ti

on

Yes 

Temperature 

protection

 

Yes (90°C) 

Mechanical dimensions 

 

 

Length X width X height (mm) 

238*177*63 

Weight 

1.5 KG 

General data 

 

 

Operating

 temperature (°C)

-

 

10~ +40 

Cooling method 

Heat sink 

Insula

tio

n class 

CLASS 1 

Protection

 level 

IP30 

 

 

 

VI. Electrical Parameters: 

PV

 

input 

Parameters 

PV maximum open circuit voltage (VDC) 

100V 

MPPT voltage (VDC) 

16~80V 

Содержание MP3743

Страница 1: ...1 12V 24V 30A MPPT Solar Charge Controller for Lithium or SLA Batteries MP3743 User Manual ...

Страница 2: ...t picture 4 5 III Description of basic functions 5 6 III Description of LCD screen 7 8 IV Operation of machine buttons and function introduction 8 9 V Wire diameter requirements 9 VI Electrical parameters 10 VII Troubleshooting 11 VIII Specifications 11 ...

Страница 3: ...rger 12 24V battery it will damage the internal discharge circuit if the voltage exceeds 33V so do not use batteries over 36V or else it may damage the charger 4 The maximum open circuit voltage of PV is 100V Do not exceed the range during use or else the charger may be damaged 5 Do not touch the heat sink in the process of product operation to avoid hot hands It is recommended to use the product ...

Страница 4: ...ter OK button 5 Green LED light off when no charging flashing during charging stay on when fully charged 6 Red LED light off when no error error alarm when the light is long on lithium battery only has 12V gear other gear flashing red light error 7 2 5V 3A USB output 8 LCD screen Remark The operations of panel items 1 4 are explained below 8 6 7 5 4 3 2 1 ...

Страница 5: ...l input a The maximum open circuit voltage of PV is 100V b PV integrates anti reverse reverse connection alarm E8 no charging please eliminate the fault c 12V battery PV input voltage range is 16 80V d 24V battery PV input voltage range is 32 80V 2 Battery output function a Identify 12 24Vbattery automatically the maximum charging current is 30A b Anti reverse connection E1 alarm 3 Load output fun...

Страница 6: ...t external analog resistance 100K 10 C 3 12V battery charging temperature 20 C 5 C 13 5 0 3 VDC test external analog resistance 39K 30 C 4 24V battery floating charge temperature 0 C 40 C 28 2 0 3 VDC test external analog resistance 430K 20 C 5 24V battery floating charge temperature 0 C 20 C 5 C 27 6 0 3 VDC test external analog resistance 100K 10 C 6 24V battery floating charge temperature 20 C 5 C...

Страница 7: ...ntering the setting parameters and turn off when exit D WIFI icon WIFI ON OFF optional default ON F Battery level icon display the corresponding icon according to the battery voltage I Load icon turn on when the load is turned on synchronized with the load switch ON J Connector three up corresponding to PV middle corresponding to battery down corresponding to load K Currently identified battery ty...

Страница 8: ...n Switch among ery voltage load voltage PV voltage and me interface in turn b Press and hold MENU to enter the parameter interface Then press to switch among the 8 interfaces in turn 1 type selec on S STD default level L LI A AGM 2 WIFI switch ON OFF default ON 3 Load undervoltage range of 12V b ies 10 11 5V default 10V s range of 24V b ies 20 23V default 20V 4 Load undervoltage recovery range of ...

Страница 9: ...d on the screen 2 UP button description Enter the parameter setting interface press UP time plus 1 voltage plus 0 1V press and hold time load voltage values can be accumulated Press in default interface after power on switch among battery voltage current load voltage current and PV voltage current 3 Down button description Enter the parameter setting interface and press DOWN time minus 1 voltage m...

Страница 10: ...3 4A Max Standby current Battery input 12V Separate MPPT charger 60 mA MPPT charger WIFI module 160 mA Protective function PV battery input high low voltage protection Yes PV battery reverse connection protection Yes Load overcurrent short circuit protection Yes Temperature protection Yes 90 C Mechanical dimensions Length X width X height mm 238 177 63 Weight 1 5 KG General data Operating temperat...

Страница 11: ...00V E7 Over temperature protec stop charging when heat sink temperature 90 C resume when temperature 60 C E8 PV reverse conne on please correct ery over and under voltage range Capacity 12V 24V low voltage pr LCD display E2 8 18V Capacity 12V 24V Over voltage protec on LCD display E5 15 31V Remark Please eliminate the fault according to the error code If the machine s does not respond the error is...

Отзывы: