5
ASSEMBLY
WARNING
• Many cover plate screws, water pipes and outlet boxes
are not properly grounded. To ensure proper ground,
grounding means must be tested by a qualified
electrician.
EXTENSION CORDS
Use proper extension cords. Make sure the extension
cord is in good condition. Use only 3-wire extension cords
have 3-prong grounding type plugs and 3-pole
receptacles which accept the tool plug. When using an
extension cord, make sure to use one heavy enough to
carry the current of the machine. An undersized cord will
cause a drop in the voltage, resulting in loss of power and
overheating. Use the table to determine the minimum wire
size (A.W.G.) extension cord.
Extension Cord Length
Wire Size…………….. A.W.G.
Up to 25 ft…………… 16 gauge
NOTE:
Using extension cords over 25 ft. long is not
recommended.
MOTOR
The sander is equipeed with a 7.5 Amps motor. The 120
Volt motor has the following specifications:
Horsepower (Peak HP) . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Amp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5
Hertz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single
RPM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3450
ELECTRICAL CONNECTIONS
•
Turn the switch off and disconnect the machine from
power source before performing any repair or
maintenance work.
•
Some electrical wiring and connection work must be
performed by a qualified electrician in accordance with
local regulations.
•
Scheme of the motor and electric wiring inside this
machine is shown in Figure 7.
•
There is a green grounding wire fastened to the frame of
the machine to provide Shock Protection. Do not
disconnect the Grounding Wire from the frame.
•
The Motor is rated for used at 120 Volts.
•
Connect this machine to 3-Conductor Power outlet with
appropriate rating only.
•
Use only 3-pronged Extension Power Cord with
appropriate rating with this machine.
•
When changing the power cord, use only 3-pronged
Power Cord with appropriate rating.
•
The Power switch is a Single Pole Rocker switch with
Locking Mechanism. Remove the Key when not in use
to prevent accidents.
Power Cord
Switch
Motor
Figure 7