54
K2 K3 | SERVICE MANUAL
Connect the mains power and switch on the amplifier, check the status of all the control LEDs, it should be as highlighted in the following
pictures:
CNTRL BOARD
AUX VOLTAGES
PSU V AUX
V RAIL
13. Internal LEDs check:
12. Error codes:
Error Code
Error Description
Board
1
192KHz clock not present
CNTRL
2
Positive 15V aux
PSU
4
Negative 15V aux
PSU
8
Positive 5V analog
PSU
100
Negative power rail Ch1
PSU
200
Negative power rail Ch2
PSU
2000
Positive power rail Ch1
PSU
4000
Positive power rail Ch2
PSU
8000
External auxiliary voltage
PSU
Check Rail Fuses
Check rail fuses Ch1 and Ch2
AMP
The error code value displayed in the main screen is the sum of the
single error code value.
Example: 4301=4000+200+100+1 means
Positive power bus Ch2 +
Negative power bus Ch2 +
Negative power bus Ch1 +
192 KHz clock not present
Expired FW 5.3.8 displayed: contact service centre.
Содержание K2 DSP+AESOP
Страница 2: ...Intentionally left blank...
Страница 11: ...11 K2 K3 SERVICE MANUAL INDEX Colour Description CONNECTION TO THE OUTPUT STAGE...
Страница 52: ...52 K2 K3 SERVICE MANUAL INDEX Menu Diagrams Main Menu Diagram DSP Settings...
Страница 68: ...68 K2 K3 SERVICE MANUAL INDEX Lastly perform a Firmware update as described in the previous section...
Страница 71: ...Intentionally left blank...