3
K2 K3 | SERVICE MANUAL
Index:
4
2. Opening the amplifier cover
5
3. Discharging the amp capacitors
5
7
5. Removing the power supply board
9
PSU Fault Finding
17
Final Inspection
21
6. Removing the amplifier output board
26
AMP outputboard Fault Finding
33
Final Inspection
34
37
38
40
10. Removing the control board (k-cntrl)
43
44
11. Copying the PAM files from a Virtual Machine
46
47
48
49
49
50
51
52
CAUTION
RISK OF ELECTRICK SHOCK
DO NOT OPEN
WE RECOMMEND THAT ALL SERVICE OPERATIONS
ARE CARRIED OUT BY A TECHNICIAN IN THE MANNER
DESCRIBED IN THIS GUIDE.
IF NOT EXPLICITLY STATED OTHERWISE, DISCONNECT THE
AMPLIFIER FROM THE MAINS BEFORE OPERATING THE
AMPLIFIER.
WARNING! INTERNAL CAPACITORS BANK COULD BE CHARGED
AND HARMFUL: TAKE CARE OF COMPLETELY DISCHARGE
INTERNAL CAPACITORS BANK BEFORE HANDLING THE DEVICE
This technical document aims to be a support guide in repairing
and low-voltage testing the K2 and K3 power amplifiers.
The troubleshooting approach will help you characterize the kind
of fault you incur. A recovery method and the related assembly
outline detail is thoroughly explained for the most common faults.
The components to be replaced are clearly shown to help their
identification. At the end of this guide you can find a detailed
list with the description and the respective Powersoft internal
reference code of the spare parts.
Tools:
This documentation contains proprietary information which is the
sole property of Powersoft S.p.A.
These documents are confidential and reserved and may not be
disclosed, reproduced and shared with third persons or used
without the express written permission from Powersoft S.p.A.
Should the service centre agreement between the two companies
be interrupted these documents must be returned to Powersoft
S.p.A. Italy or proof of their destruction be provided.
Required Instrumentation
Q.ty Example/Comments
Dual stabilized power supply 30 Vdc 5 A
2
APLHA Electronica mod. AL852D or equivalent
Diigital Oscilloscope 50 Mhz
1
TEKTRONIK TBS – 1052B-EDU or equivalent
Signal generator
1
Audio frequency range 10-20kHz, output level 3Vrms
Variac
1
Toroidal 3 KW (Mono phase)
Dummy load 1500 W 8 Ohm
1
TE CONNECTIVITY / CGS TE1500B10RJ Resistor
Soldering Station
1
WELLER PU81 + WSP80 or equivalent
SMD rework soldering station
1
GORDAK 952 or equivalent
Digital Multimeter
1
FLUKE 179 or equivalent
Pc with at least 1 eth board
1
•
Phillips PH 0 and PH 1 screwdrivers
•
Small cutter
•
Tweezers
•
Testing components kit
PLEASE NOTE THAT THE ONLY END USER AUTHORIZED MAINTENANCE PROCEDURE IS THE FILTER CLEANING PROCEDURE, ANY
EVIDENCE OF OTHER OPERATION CARRIED BY UNAUTHORIZED PERSONNEL WILL RESULT IN IMMEDIATE WARRANTY LOSS.
Содержание K2 DSP+AESOP
Страница 2: ...Intentionally left blank...
Страница 11: ...11 K2 K3 SERVICE MANUAL INDEX Colour Description CONNECTION TO THE OUTPUT STAGE...
Страница 52: ...52 K2 K3 SERVICE MANUAL INDEX Menu Diagrams Main Menu Diagram DSP Settings...
Страница 68: ...68 K2 K3 SERVICE MANUAL INDEX Lastly perform a Firmware update as described in the previous section...
Страница 71: ...Intentionally left blank...