29
K2 K3 | SERVICE MANUAL
INDEX
Final inspection (DC mains)
By means of the
, and the
, connect the board to two DC
power supply and slowly increment the voltages to the
illustrated values in order to check the absorption. (Fig.
31)
Mains Inlet: 50V: 20mA ± 10%
CN5: 18V: 40mA ± 10%
If the outcome is positive,repeat the test inverting the
polarity of the
in order to check the
Diodes Bridge integrity.
(Fig. 31)
50V 20mA
18V 40mA
50V 20mA
18V 40mA