24
K2 K3 | SERVICE MANUAL
Cleaning the Heatsink:
Peel off the SilPad from both sides of the heatsink
Using a plastic scraper, remove the leftover glue
Dampen a clean cloth with some isopropyl alcohol and wipe off
the excess residues.
Delicately swab the residues off the components.
Replacing the Gap Pads:
Carefully scrape off all residues from the heatsink-
mounted components, remove all residues of dirt and
glue.
Lay the gap pad between the components and the
heatsink, and tighten all the retainer spring’s screws.