0 1 0  

Counter for stitches 

0 2 4  

Machine angle 

0 1 1  

Counter for sewing pieces 

0 2 5  

The sampling voltage of pedal

 

0 1 3  

State of encoder

 

0 2 6  

The ratio between motor and machine

 

0 2 0  

DC voltage

 

0 2 7  

The total used time(hours) of motor

 

0 2 1  

Machine speed 

0 2 8  

The sampling voltage of interaction

 

0 2 2  

The phase current   

0 2 9  

Software version   

0 2 3  

Initial electrical angle 

0 3 0 - 0 3 7  

The history record of error codes 

3.3 

The Warning Message   

Alarm code 

Description

 

Corrective

 

 

Fuel filling warning 

Fuel filling. Press P key to clear. 

 

Count over for stitches 

The counter reaches the limit. Press P key to reset the counter. 

 

Count over for sewing pieces

The counter reaches the limit. Press P key to reset the counter.

 

 

Emergency stop 

Press the key of emergency stop to clear.   

 

Lift needle locking 

Then press the needle lifting locking button, can eliminate the needle lifting 

locking state. 

 

Power is off 

Please wait for 30 seconds, then turn on the power switch. 

 

Safety switch alarm 

Adjust the machine to the correct position. 

3.4  

Error 

Mode 

If the error code appears, please check the following items first: 

1.Make sure the machine has been connected correctly;      2.    Reload the factory setting and try again. 

Error Code  

Description 

 Solution  

E r r - 0 1  

 Hardware overcurrent 

E r r - 0 2  

Software overcurrent   

Turn off the power switch, and restart after 30 seconds. If the controller still does not 

work, please replace it and inform the manufacturer. 

E r r - 0 3  

Under-voltage  

- Check mains voltage   - Stabilize mains voltage  

E r r - 0 4  

 Over-voltage when the 

machine is off   

E r r - 0 5  

Over-voltage in operation 

Disconnect the controller power and check if the input voltage is too high (higher than 

264V). If yes, please restart the controller when the normal voltage is resumed. If the 

controller still does not work when the voltage is at normal level, please replace the 

controller and inform the manufacturer. 

E r r - 0 6  

Short circuit of solenoid 

voltage 24V 

- Take plug out, if error continues, replace control box      - Test inputs/ outputs for 

24V short circuit 

E r r - 0 7  

Motor current measuring 

failure  

Turn off the system power, restart after 30 seconds to see if it works well. If such failure 

happens frequently, seek technical support.   

E r r - 0 8  

Sewing motor blocked   

- Eliminate sluggish movement in the sewing machine 

- Replace encoder      - Replace sewing motor   

E r r - 0 9  

Brake circuit failure   

Check the brake resistor plug on the electric board.      Replace the control box 

E r r - 1 0  

Communication failure   

Check the connection and if necessary plug in.      Replace the control box. 

E r r - 1 1  

Machine head needle 

positioning failure   

Check if the connection line between machine head synchronizer and controller is 

loose or not, restore it and restart the system. If it still does not work, please replace the 

controller and inform the manufacturer. 

E r r - 1 2  

Initial motor electrical angle 

failure  

- Try 2 to 3 more times after power down 

-   if it still does not work, please replace the controller and inform the manufacturer.   

Содержание ASE59

Страница 1: ... manual carefully also with related manual for the machinery before use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and m...

Страница 2: ...ssive distortion to ensure safe use 2 Operation Panel Instructions 2 1 Operation Panel Display Instruction Fig 2 1 Operation Panel Key Functions Key Name Description Parameter setting key Use the key to switch to the program mode The key is parameters confirm key and back to the previous menu until the operator sewing mode state In addition work with other key to set a higher level of the paramete...

Страница 3: ...ting Mode Switch during all presser foot lifting mode when pressing the key is lit No lifting lifting after trimming cycle only lifting at machine stop only lifting at machine stop and after trimming cycle both One shot sewing selection In constant stitch sewing a Press the key is lit automatic performed number of stitches of every section b Press key again the lights went out to finish rest the s...

Страница 4: ...B none 4 AB ABAB none 1 1 C 0 9999 0 Tens digit for each segment of A B C D 1 1 D 0 9999 0 Tens digit for each segment of E F G H 1 1 E 0 9999 0 Tens digit for each segment of A B D 1 1 F 0 359 0 Back tacking under angle control 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 ...

Страница 5: ...en count over panel alarms and motor stops after trimming 6 Count down by trimming When count over panel alarms and motor stops after trimming 1 5 3 1 100 1 The proportion coefficient of the pieces counter 1 5 4 1 9999 1 Maximum pieces of the counter 1 5 5 0 4 0 Count mode selection For Sewing Piece 0 The counter is invalid 1 Count up by pieces When count over counter will be auto reset 2 Count do...

Страница 6: ...ead release output end angle LE Down needle position angle is the reference and this value should be bigger than LS 2 1 3 1 999 1 Thread release output start delay time T1 ms 2 1 4 1 999 10 Thread release output end delay time T2 ms after up needle position 2 1 5 0 1 1 Wiper function 0 disable 1 enable 2 1 6 1 999 10 Wiper output delay time ms 2 1 7 1 9999 70 Wiper output time ms 2 1 9 0 1 0 Threa...

Страница 7: ...r still does not work please replace it and inform the manufacturer E r r 0 3 Under voltage Check mains voltage Stabilize mains voltage E r r 0 4 Over voltage when the machine is off E r r 0 5 Over voltage in operation Disconnect the controller power and check if the input voltage is too high higher than 264V If yes please restart the controller when the normal voltage is resumed If the controller...

Страница 8: ...wn simultaneously 3 2 4 0 0 0 0 Step 3 Press P key the new up needle position is preserved and the parameter is set to zero 4 2 The Recovery of Default Factory Setting 1 2 4 0 0 0 0 Step 1 Press P key then enter the monitor mode 2 Step 2 Press key for about 5 seconds then Default Factory Setting is recovered displaying as left LCD 3 8 8 8 8 8 8 When the LCD is displayed as 8888888 the recovery is ...

Отзывы: