7/8
No. Description
No.
Description
0 1 0
Counter for stitches
0 2 4
Machine angle
0 1 1
Counter for sewing pieces
0 2 5
The sampling voltage of pedal
0 1 3
State of encoder
0 2 6
The ratio between motor and machine
0 2 0
DC voltage
0 2 7
The total used time(hours) of motor
0 2 1
Machine speed
0 2 8
The sampling voltage of interaction
0 2 2
The phase current
0 2 9
Software version
0 2 3
Initial electrical angle
0 3 0 - 0 3 7
The history record of error codes
3.3
The Warning Message
Alarm code
Description
Corrective
Fuel filling warning
Fuel filling. Press P key to clear.
Count over for stitches
The counter reaches the limit. Press P key to reset the counter.
Count over for sewing pieces
The counter reaches the limit. Press P key to reset the counter.
Emergency stop
Press the key of emergency stop to clear.
Lift needle locking
Then press the needle lifting locking button, can eliminate the needle lifting
locking state.
Power is off
Please wait for 30 seconds, then turn on the power switch.
Safety switch alarm
Adjust the machine to the correct position.
3.4
Error
Mode
If the error code appears, please check the following items first:
1.Make sure the machine has been connected correctly; 2. Reload the factory setting and try again.
Error Code
Description
Solution
E r r - 0 1
Hardware overcurrent
E r r - 0 2
Software overcurrent
Turn off the power switch, and restart after 30 seconds. If the controller still does not
work, please replace it and inform the manufacturer.
E r r - 0 3
Under-voltage
- Check mains voltage - Stabilize mains voltage
E r r - 0 4
Over-voltage when the
machine is off
E r r - 0 5
Over-voltage in operation
Disconnect the controller power and check if the input voltage is too high (higher than
264V). If yes, please restart the controller when the normal voltage is resumed. If the
controller still does not work when the voltage is at normal level, please replace the
controller and inform the manufacturer.
E r r - 0 6
Short circuit of solenoid
voltage 24V
- Take plug out, if error continues, replace control box - Test inputs/ outputs for
24V short circuit
E r r - 0 7
Motor current measuring
failure
Turn off the system power, restart after 30 seconds to see if it works well. If such failure
happens frequently, seek technical support.
E r r - 0 8
Sewing motor blocked
- Eliminate sluggish movement in the sewing machine
- Replace encoder - Replace sewing motor
E r r - 0 9
Brake circuit failure
Check the brake resistor plug on the electric board. Replace the control box
E r r - 1 0
Communication failure
Check the connection and if necessary plug in. Replace the control box.
E r r - 1 1
Machine head needle
positioning failure
Check if the connection line between machine head synchronizer and controller is
loose or not, restore it and restart the system. If it still does not work, please replace the
controller and inform the manufacturer.
E r r - 1 2
Initial motor electrical angle
failure
- Try 2 to 3 more times after power down
- if it still does not work, please replace the controller and inform the manufacturer.