6/8
NO. Range Default
Description
1
、
Press
P
key can modify the administrator parameter table;
2、
The digital tube display
,
It is required to enter password to the administrator mode. Press the corresponding
key and
key to change the password value;
3
、
Press
P
key, If the password is correct, that is to enter the technical parameters set mode,show
P2XX.
Press
key, the current
parameter value is displayed;
4
、
Press the corresponding
key and
key to change the parameter value or selection parameter number;
5
、
At last press
key to exit parameter setting mode,return to sewing work mode.
2 0 0
0
/
1
/
2 0
Trimming mode selection:0: lockstitch machine1: interlock machine: Needle stops at the up
position and trim. 2:
overlock machine: manual trimming
2 0 1
0
~
359 0
Mechanical angle after trimming
2 0 3
5-359 10
Trimming output start angle TS (down needle position angle as the reference point)
2 0 4
10-359 120
Trimming output end angle TE (Down needle position angle is the reference and this value
should be bigger than TS)
2 0 A
10-60 20
Motor torque improvement coefficient during trimming
2 1 1
5-359 25
Thread release output start angle LS (down needle position angle as the reference point)
2 1 2
10-359 350
Thread release output end angle LE (Down needle position angle is the reference and this
value should be bigger than LS)
2 1 3
1-999 1
Thread release output start delay time T1 (ms)
2 1 4
1
~
999 10
Thread release output end delay time T2 (ms) after up needle position
2 1 5
0
/
1 1
Wiper function 0: disable 1: enable
2 1 6
1
~
999 10
Wiper output delay time (ms)
2 1 7
1
~
9999 70
Wiper output time (ms)
2 1 9
0
/
1 0
Thread clamp function 0: disable 1: enable
2 1 A
10-359 120
Thread clamp start angle
2 1 B
11-359 318
Thread clamp end angle
2 1 E
11-359 160
The angle of presser foot solenoid off during thread clamping
2 2 0
200
~
360 360
Stop position after trimming (motor can stop with a reverse angle)
2 3 1
0
/
1 0
Auto test mode: 0: stitches mode 1: time mode
2 3 2
0
~
1000 300
Safe switch filtering time (ms)
2 3 4
0
/
1
0
Motor direction: 1: CCW 0: CW
2 4 0
0
~
9999 1000
The ratio between motor and machine (1000 stands for 1:1)
2 4 2
0
~
359 0
Up needle stop angle (After detecting the synchronizer signal)
2 4 3
0
~
359 175
Down needle stop angle
2 4 4
0~800 200
Running delay time when presser footer comes down (ms)
2 4 7
0
~
2000 0
The alarm time for adding oil (hours), disabled when setting 0
3.3 Monitor mode
1. Pressing
P
+
ke to enter monitor mode.The digital tube will display
2 4 0 0 0 0
.
2. Press
and
key to adjust the parameter number, and the para value is shown at the same time.
3. Press