Roller AC Servo System 

 HMI-14 User Manual 

 

 

 
 
 
 
 
 

 
 
 
 
 

 

 

 

1 Installation Instructions

 

1.1 Product specifications 

Product Type 

ASE59

 

Supply Voltage 

AC 220 ± 44 V

Power frequency 

50Hz/60Hz 

Maximum output power 

550/750W 

1.2 Interface plug connections 

The pedals and the machine head of the connector plug are mounted to the corresponding position in the controller back of 

socket, as shown in Figure 1-1. Please check if the plug is inserted firmly.   

                                                                                                                                     

                                                                                                                                     

                                                                                                                                     

                                                                                                                                     

                                                                                                                                   

 

 

Fig.1-1 Controller Socket Diagram 

① 

Foot lifter solenoid socket; 

 Machine head solenoid socket; 

 Lifter needle lock    socket; 

Pedals socket;

 

 

 

 

  The use of the normal force are not inserted into the plug and socket, please check whether the matching, direction or 

needle insertion direction is correct! Lighting interface and presser foot lifting electromagnet interface is a 1*2 interface, head 

lamp interface using black interface, please pay attention to the distinction . 

·

 

Please read this manual carefully, also with related manual for the machinery before use the controller.

 

·

 

For installing and operating the controller properly and safely, qualified personnel are required.

 

·

 

Please try to stay away from arc welding equipment, in order to avoid electromagnetic interference and 

malfunction of the controller.   

·

 

Keep in room bellow 45° and above 0°   

·

 

Do not humidity below 30% or above 95% or dew and mist of places.   

·

 

Install the control box and other components, turn off the power and unplug the power cord. 

·

 

To prevent interference or leakage accidents, please do the ground work, the power cord ground wire 

must be securely connected to an effective way to earth. 

·

 

All parts for the repair provided by the Company or approved before use. 

·

 

Performing any maintenance action, you must turn off the power and unplug the power cord. There are 

dangerous high voltage control box, you must turn the power off after one minute before opening the 

control box. 

·

 

This manual marked with the symbol of the Department of Safety Precautions must be aware of and 

strictly adhered to, so as not to cause unnecessary damage. 

 

Safely Instruction

 

Содержание ASE59

Страница 1: ... manual carefully also with related manual for the machinery before use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and m...

Страница 2: ...ssive distortion to ensure safe use 2 Operation Panel Instructions 2 1 Operation Panel Display Instruction Fig 2 1 Operation Panel Key Functions Key Name Description Parameter setting key Use the key to switch to the program mode The key is parameters confirm key and back to the previous menu until the operator sewing mode state In addition work with other key to set a higher level of the paramete...

Страница 3: ...ting Mode Switch during all presser foot lifting mode when pressing the key is lit No lifting lifting after trimming cycle only lifting at machine stop only lifting at machine stop and after trimming cycle both One shot sewing selection In constant stitch sewing a Press the key is lit automatic performed number of stitches of every section b Press key again the lights went out to finish rest the s...

Страница 4: ...B none 4 AB ABAB none 1 1 C 0 9999 0 Tens digit for each segment of A B C D 1 1 D 0 9999 0 Tens digit for each segment of E F G H 1 1 E 0 9999 0 Tens digit for each segment of A B D 1 1 F 0 359 0 Back tacking under angle control 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 ...

Страница 5: ...en count over panel alarms and motor stops after trimming 6 Count down by trimming When count over panel alarms and motor stops after trimming 1 5 3 1 100 1 The proportion coefficient of the pieces counter 1 5 4 1 9999 1 Maximum pieces of the counter 1 5 5 0 4 0 Count mode selection For Sewing Piece 0 The counter is invalid 1 Count up by pieces When count over counter will be auto reset 2 Count do...

Страница 6: ...ead release output end angle LE Down needle position angle is the reference and this value should be bigger than LS 2 1 3 1 999 1 Thread release output start delay time T1 ms 2 1 4 1 999 10 Thread release output end delay time T2 ms after up needle position 2 1 5 0 1 1 Wiper function 0 disable 1 enable 2 1 6 1 999 10 Wiper output delay time ms 2 1 7 1 9999 70 Wiper output time ms 2 1 9 0 1 0 Threa...

Страница 7: ...r still does not work please replace it and inform the manufacturer E r r 0 3 Under voltage Check mains voltage Stabilize mains voltage E r r 0 4 Over voltage when the machine is off E r r 0 5 Over voltage in operation Disconnect the controller power and check if the input voltage is too high higher than 264V If yes please restart the controller when the normal voltage is resumed If the controller...

Страница 8: ...wn simultaneously 3 2 4 0 0 0 0 Step 3 Press P key the new up needle position is preserved and the parameter is set to zero 4 2 The Recovery of Default Factory Setting 1 2 4 0 0 0 0 Step 1 Press P key then enter the monitor mode 2 Step 2 Press key for about 5 seconds then Default Factory Setting is recovered displaying as left LCD 3 8 8 8 8 8 8 When the LCD is displayed as 8888888 the recovery is ...

Отзывы: