The serial number is 

located on the left 

had end plate

 

9. Display and Control Elements: 

Take note of all control elements before first commissioning.

 

9.2 LED status Indicators  

 

 

20 LED Power Bar

 

The power bar will only operate when savings are being made.  The power bar indicates when ERS is diverting 

energy to the load.  The more LEDs  illuminated, from left to right, the more power is being diverted.  

 

When the two outer LEDs are illuminated, the load is switched off. This could indicate, for example, that the 

water is now hot.  If an over temperature situation occurs, the 3 centre LEDs above the boost button will 

illuminate. ERS will stop operation for 2 minutes before automatically re

-

booting. Should the over temperature 

situation still exist, the process will repeat until the internal temperature has fallen. During this period, ERS will 

not drive the load.   

 

 

Boost button LED

 

On start up, the LED on the boost button will flash five times.  During manual boost operation, the LED will be 

permanently illuminated. This will switch off automatically after the timed period. The power bar will not 

 

illuminate during manual boost operation. 

 

 

 

 

 

Manual Boost Button

 

20 LED Power 

Bar Indicator

 

9.1 Switch ON and OFF

 

 

During installation, a 20A double pole switch with neon should be installed close to the ERS device.

 

This acts as an isolation switch should the user wish to isolate the ERS unit from the mains supply. 

 

Ensure the supply MCB is in the ON position, then switch the isolator to the ON position.  The blue LED in 

the boost button will flash 5 times indicating ERS is booting up.  During boot up ERS is performing an 

auto calibration procedure and is ready to use once the LED stops flashing. Ensure that the heating load 

is switch to the ON position, if export is detected ERS will begin to operate automatically.  

 

To switch off ERS, turn the isolation switch to the OFF position. 

 

 

13

 

Содержание ERS MINI

Страница 1: ...Important Information for your PowerFlow ERS MINI Installation and User Manual IMPORTANT SAFETY INFORMATION PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE COMMENCING WORK...

Страница 2: ...to support Great British manufacturing By purchasing PowerFlow Products you are supporting the development of this important technology so future generations can benefit and prosper from cleaner green...

Страница 3: ...Connection panel 5 4 Ventilation mounting clearances 5 5 mounting clearances multiple devices Page 10 6 System Design 6 1 AC circuit protection Page 11 7 Connector Assemblies 7 1 Power Connections 7...

Страница 4: ...to be connected to an AC supply network with a nominal supply of 230V 50Hz ERS MINI is designed to work alongside a grid connected renewable generator such as a wind or solar system E R S MINI does no...

Страница 5: ...RS enclosure may become hot to touch Always use caution when touching the enclosure after long periods of operation 2 DO NOT place objects over the enclosure PowerFlow ERS uses the metal enclosure to...

Страница 6: ...R S MINI to work during any time of the day and together with the solar or wind generator to ensure that maximum energy capture is possible During times when export occurs the amount of energy availa...

Страница 7: ...tions should be considered prior to installation A B C D E F G H Object Quantity Description A 1 E R S MINI Device with integral mounting brackets B 1 Current measurement clamp CT C 1 1 x 3 PIN IEC Ma...

Страница 8: ...nt such as scaffolding or lifting platforms Non compliance with this recommendation may restrict servicing Extended Mounting Criteria The connection panels must always face horizontally DO NOT MOUNT U...

Страница 9: ...40mm 50mm Use 3 core 1 5mm flex to isolator then 2 5mm to consumer board IEC Power OUT connector 20mm Display Power Bar 5 2 Product Dimensions 5 3 Overview of Connection Panel Object Description A Ma...

Страница 10: ...s sufficient and suitable space for heat dissipation 5 4 Ventilation Mounting Clearances 100mm 100mm 150mm 50mm 5 5 Mounting Clearances for Multiple Devices Horizontal Installation 100mm minimum betwe...

Страница 11: ...d For further information please refer to the warranty documentation It is important to take note of the following notices Failure to do so may result in danger to persons damage to property or invali...

Страница 12: ...cable 1 5mm 3 core flex PIN 1 ERS Live OUT brown 3 PIN IEC Power IN Connector D PFM PC 03 FM Recommended cable 1 5mm 3 core flex PIN 2 Earth Green Yellow PIN 3 Neutral OUT Blue PIN 1 ERS Live IN Brown...

Страница 13: ...tive heating element connected to the ERS driven circuit Failure to observe this will result in damage IMPORTANT IMPORTANT It is essential that the current clamp CT is connected between the main prima...

Страница 14: ...not drive the load Boost button LED On start up the LED on the boost button will flash five times During manual boost operation the LED will be permanently illuminated This will switch off automatica...

Страница 15: ...o the heating load should it be required To enable the manual boost push the button once an audible click can be heard and the LED will turn on indicating the manual boost has been started At this poi...

Страница 16: ...d off The illustration below demonstrates how the display would appear in the above example 9 6 Over Temperature ERS MINI has an internal temperature sensor for safety If an over temperature situation...

Страница 17: ...up and with adequate ventilation 2 All cable runs are correctly fixed and supported and an AC isolator has been installed 3 The main power cable has been terminated observing the correct pin numbers 4...

Страница 18: ...mmersion switch next to the hot water tank must be left in the ON position Power will only be sent to the immersion heater when export energy is available Ensure there is enough export energy ERS will...

Страница 19: ...Wind Hydro Recommended renewable generator size 2 0kW Output load Resistive Only Output control range 5 100 Minimum output load 300 W Minimum export power level Export tracking range 25W 25 200W Gener...

Страница 20: ...www powerflowenergy com...

Отзывы: