32
7.3
Battery temperature sensor and voltage sense
In charger mode, battery temperature compensation is automatically used, if sensor is connected
and selected algorithm has temperature compensation defined.
In charger mode, DC cable voltage loss compensation can be done programmatically using
charging parameter "cable resistance". Compensation can also be done by hardware using sense
wires. This method works in all modes.
Length 2.5m to first joint, total 3.2 m, IP67 at charger end, IPxx at fuse holder, other joints molded.
The black rectangular piece is temperature sensor and is attached externally to the battery pack.
Black and red ring terminals are connected to - and + poles. Positive wire also has a fuse (3 A, type
ATO).
For Robust models with RJ11 connectors, similar accessory is available.
7.4
CAN cable
CAN cable for Robust 2300 and 3000 charger is as standard 2 m in length, IP67, not terminated.
Not terminated both in terms of second connector and line impedance.
HD26M pin
wire color signal
10
white
CAN_L
1
brown
CAN_H