background image

Page 22  — English

WARRANTY

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The U.S. EPA, Environment Canada,  and OWT Industries, Inc., 
are pleased to explain the evaporative emission control system’s 
warranty on your small off-road equipment. New equipment that 
uses small off-road engines must be designed, built, and equipped 
to meet the stringent evaporative standards. OWT Industries, Inc., 
must warrant the evaporative emission control system on your 
small off-road equipment for the period listed below, provided 
there has been no abuse, neglect or improper maintenance of 
your equipment. 
Your evaporative emission control system may include parts such 
as: carburetors, fuel tanks, fuel line, fuel caps, valves, canisters, 
filters, vapor hoses, clamps, connectors, and other associated 
components. 

MANUFACTURER’S WARRANTY COVERAGE:

This evaporative emission control system is warranted for three 
years. If any evaporative emission-related part on your equipment is 
defective, the part will be repaired or replaced by OWT Industries, Inc. 

OWNER’S WARRANTY RESPONSIBILITIES:

  As the small off-road equipment owner, you are responsible 

for performance of the required maintenance listed in your 
operator’s manual. OWT Industries, Inc., recommends that you 
retain all receipts covering maintenance on your small off-road 
equipment, but OWT Industries, Inc.,  cannot deny warranty 
solely for the lack of receipts.

  As the small off-road equipment owner, you should, however, 

be aware that OWT Industries, Inc., may deny you warranty 
coverage if your small off-road equipment or a part has failed 
due to abuse, neglect, or improper maintenance or unapproved 
modifications.

  You are responsible for presenting your small off-road equip-

ment to a OWT Industries, Inc., distribution center or service 
center as soon as the problem exists. The warranty repairs 
should be completed in a reasonable amount of time, not to 
exceed 30 days.

If you have a question regarding your warranty coverage, you 
should contact OWT Industries, Inc., at 1-877-617-3501.

DEFECTS WARRANTY REQUIREMENTS:

(a) The warranty period begins on the date the equipment is de-

livered to an ultimate purchaser. 

(b) General Evaporative Emissions Warranty Coverage. The equip-

ment must be warranted to the ultimate  purchaser and any 
subsequent owner that the evaporative emission control system 
when installed was: 

  (1) Designed, built, and equipped so as to conform  with all 

applicable regulations; and 

  (2) Free from defects in materials and workmanship that cause 

the failure of a warranted part for a period of three years.

(c) The warranty on evaporative emissions-related parts  will be 

interpreted as follows:

  (1) Any warranted part that is not scheduled for replacement 

as required maintenance in the written instructions must be 
warranted for the warranty period defined in subsection (b)
(2). If any such part fails during the period of warranty cov-
erage, it must be repaired or replaced by the manufacturer 
issuing the warranty. Any such  part repaired or replaced 

under the warranty must be warranted for a time not less 
than the remaining warranty period. 

  (2) Any warranted part that is scheduled only for regular inspec-

tion in the written instructions must be warranted for the 
warranty period defined in subsection (b)(2). A statement in 
such written instructions to the effect of “repair or replace as 
necessary” will not reduce the period of warranty coverage. 
Any such part repaired or replaced under warranty must be 
warranted for a time not less than the remaining warranty 
period. 

  (3) Any warranted part that is scheduled for replacement as 

required maintenance in the  written instructions must be 
warranted for the period of time prior to the first scheduled 
replacement point for that part. If the part fails prior to the 
first scheduled replacement, the part must be repaired or 
replaced by the manufacturer issuing the warranty. Any such 
part repaired or replaced under warranty must be warranted 
for a time not less than the remainder of the period prior to 
the first scheduled replacement point for the part. 

  (4) Repair or replacement of any warranted part  under the 

warranty provisions of this article must be performed at no 
charge to the owner at a warranty station. 

  (5) Notwithstanding the provisions of subsection  (4) above, 

warranty services or repairs must be provided at distribution 
centers that are franchised to service the subject equipment. 

  (6) The owner must not be charged for diagnostic labor that 

leads to the determination that a warranted part is in fact 
defective, provided that such diagnostic work is performed 
at a warranty station. 

  (7) Throughout the evaporative emission control system’s war-

ranty period set out in subsection (b)(2), the manufacturer 
issuing the warranty must maintain a supply of warranted 
parts sufficient to meet the expected demand for such parts. 

  (8) Manufacturer approved replacement parts must be used in 

the performance of any warranty maintenance or repairs and 
must be provided without charge to the owner. Such use 
will not reduce the warranty obligations of the manufacturer 
issuing the warranty. 

  (9) The use of any add-on or modified parts will be grounds 

for disallowing a warranty claim made in accordance with 
this article. The manufacturer issuing the warranty will not 
be liable under this Article to warrant failures of warranted 
parts caused by the use of an add-on or modified part. 

 

EMISSION WARRANTY PARTS LIST:

1)  Fuel Tank
2)  Fuel Cap
3)  Fuel Line
4)  Carbon Canister
5)  Vapor Hoses
6)  Hose Clamps
7)  Hose Connectors
8)  Vapor/Fuel Check Valve
Written instructions for the maintenance and use of the evaporative 
emissions control system by the owner shall be furnished with all 
new small off-road equipment.

OWT INDUSTRIES, INC., FEDERAL EMISSION CONTROL WARRANTY STATEMENT

Содержание PS905000A

Страница 1: ...o Guarde este manual del operador y est dielo frecuentemente para lograr un funcionamiento seguro y continuo de este producto Le agradecemos su compra NEUTRAL BONDED TO FRAME PUNTO NEUTRO CONECTADO AL...

Страница 2: ...por del tanque de combustible M Ground terminal terminal de conexi n a tierra N Fuel valve v lvula de combustible O Handle lock pin pasador de seguro del mango P AC circuit breakers disyuntors de circ...

Страница 3: ...a D Bolt perno A Hitch pin pasador del enganche B Washer arandela C Wheel rueda D Axle eje E U bracket soporte en U Fig 6 B A D C B A D E A B A Lanyard correa B Handle lock pin pasador de seguro del m...

Страница 4: ...e aire B Air filter cover tapa del filtro de aire C Filter element elemento de filtro D Air filter unit unidad del filtro de aire A Oil drain plug tap n de drenaje del aceite B Oil cap dipstick tapa d...

Страница 5: ...e purga C Fuel valve v lvula de combustible Fig 17 Fig 18 A Carburetor drain screw tornillo de drenaje del carburador Fig 22 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible...

Страница 6: ...l Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used it shoul...

Страница 7: ...o not start or operate the engine in a confined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and ext...

Страница 8: ...e the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the generator in we...

Страница 9: ...use severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift the generat...

Страница 10: ...damp locations Using a generator indoors CAN KILL YOUINMINUTES Generatorexhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVENIFdoorsandwindo...

Страница 11: ...f the engine if the lubricant level falls below a safe limit GROUNDING WARNING National Electric Code requires genera tor to be grounded to an approved earth ground HOT SURFACE WARNING Do not touch th...

Страница 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Страница 13: ...r power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest...

Страница 14: ...SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of oil in the crankcase is insufficient OIL CAP DIPSTICK Remove the oil fill cap to check and add lubricant to the generat...

Страница 15: ...with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration...

Страница 16: ...thing CO Never use a generator inside homes garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Us ing a fan or opening windows and doors d...

Страница 17: ...n detergent or 2 stroke engine lubricants will damage the engine and should not be used Turn the fuel valve to the OFF position Unscrew the oil cap dipstick and remove Wipe dipstick clean and re seat...

Страница 18: ...witch until the engine stops To stop the unit quickly in an emergency Press and hold the STOP switch until the engine stops WARNING While operating and storing keep at least 3 feet of clear ance on al...

Страница 19: ...sed lubricant as it drains Unscrew the oil drain plug and remove Allow lubricant to drain completely NOTE Drain the lubricant while the engine is still warm but not hot Warm lubricant will drain quick...

Страница 20: ...d from the tank close the fuel valve and reinstall fuel line securely on petcock Reinstall fuel valve knob in generator housing Push for ward until knob snaps securely into position DRAINING THE CARBU...

Страница 21: ...n generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein S...

Страница 22: ...heckairfilterelement Cleanor replace as needed Drain fuel and carburetor Refuel with fresh gasoline If problem continues contact your nearest authorized service center AC receptacle does not work Circ...

Страница 23: ...not cover Tune ups Spark Plugs Carburetor Carburetor Adjustments Ignition Filters Oil Change Wear items Recoil Starter Rope Engine Brushes Cotter Pins Wheels Warranty is voided if the customer fails t...

Страница 24: ...rosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4 Dirt...

Страница 25: ...gines a Applicability This warranty shall apply to 2012 model year engines The ECS War ranty Period shall begin on the date the new engine or equipment is purchased by delivered to its original end us...

Страница 26: ...in subsection b 2 If any such part fails during the period of warranty cov erage it must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced under the w...

Страница 27: ...ras pr cticas para establecer una buena fuente de conexi n a tierra Si se utiliza una barra de acero o de hierro ste debe ser de 15 9 mm 5 8 pulg de di metro y si se utiliza una barra no ferrosa sta d...

Страница 28: ...arrancarofuncionarelmotorenunespacioconfinado de edificio cerca de ventana abiertas o en otro rea sin ventilaci n donde se puedan recolectar las emanaciones de mon xido de carbono El mon xido de carbo...

Страница 29: ...erficie estable horizontal con una pendiente no mayor de 4 Utilice la unidad en un rea bien ventilada e iluminada aislada de las reas de trabajo para evitar la interferencia del ruido Si se utiliza el...

Страница 30: ...reducir el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto Alerta de condiciones h medas No exponga la unidad a la lluvia ni la use en lugares h...

Страница 31: ...xido de carbono que puede causar p rdida del conocimiento a la MUERTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas La omisi n de conectar a tierra adecuadamente el ge...

Страница 32: ...lubricante desciende abajo del l mite de seguridad ADVERTENCIA ACERCA DE LA CONEXI N A TIERRA El Reglamento Nacional de Electricidad exige que el generador est conectado a una tierra aprobada ADVERTEN...

Страница 33: ...ra estimar la potencia necesaria en vatios para arrancar los motores el ctricos no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herrami...

Страница 34: ...te deje que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional Nunca a ada m s cargas que las que permita la capacidad delgenerador Tengaespecialcuidadoalconsiderarlascargas...

Страница 35: ...detenci n del motor cuando el nivel de aceite en el c rter es insuficiente TAPA DE RELLENO DE ACEITE VARILLA MEDIDORA DE ACEITE Retire la tapa de relleno de aceite para revisar el nivel y a adir lubr...

Страница 36: ...alteraci n o modificaci n constituye maltrato y puede causar una condici n peligrosa y como consecuencia posibles lesiones corporales graves ADVERTENCIA No intente accionar el generador antes de term...

Страница 37: ...l dese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puedesufririntoxicaci npormon xidodecarbono PELIGRO El incumplimiento de conectar correctamente a tierra el generador puede resultar en el...

Страница 38: ...O DE ESTABILILZADOR DE COMBUSTIBLE El combustible se hace viejo se oxida y descompone al paso del tiempo Agregando estabilizador de combustible no incluido se prolonga la vida til del combustible y se...

Страница 39: ...tuaci n de emergencia Presione y sostenga el interruptor del apagado hasta que el motor se detenga ADVERTENCIA Tanto en funcionamiento como al guardarlo mantenga siempre 91 4 cm 3 pies de espacio libr...

Страница 40: ...renaje del aceite y ret relo Permita que se drene completamente el lubricante NOTA Drene el aceite mientras est tibio el motor no caliente el aceite tibio se drena con mayor facilidad y compleci n ADV...

Страница 41: ...ar el conducto en la llave de purga Vuelva a colocar la perilla de la v lvula del combustible en el alojamiento del generador Empuje hacia adelante hasta que la perilla quede segura en la posici n DRE...

Страница 42: ...imiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de...

Страница 43: ...calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combustible y el carburador Reabastezca de gasolina fresca la unidad Si el problema contin a comun quese...

Страница 44: ...ta garant a no cubre Afinaci n Buj as carburador ajustes del carburador encendido filtros cambio de aceite Desgaste de piezas Cuerda del arrancador retr ctil escobillas del motor pasadores de chaveta...

Страница 45: ...cargas o por volantes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados o faltantes 4 El desgaste relacionado con la suciedad o mugre causad...

Страница 46: ...de Garant a del ECS comenzar a regir a partir de la fecha en que se adquiri entreg el nuevo motor o equipo a su comprador propietario final original y mantendr su vigencia durante los 24 meses consec...

Страница 47: ...to debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Si cualquier de dichas partes fallan durante el tiempo de la cobertura de la garant a debe ser reparada o reemplazada po...

Страница 48: ...plicamos llamar al 1 877 617 3501 PIEZAS DE REPUESTO El n mero de modelo de este producto se encuentra en una placa o etiqueta pegada a la caja del motor Le recomendamos anotar el n mero de serie en e...