background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

2

PFWRC66B1S 

 

Wet Rotor Circulator Pumps

General Safety Information

® Power-Flo  is a registered trademark of Power-Flo 

Technologies Inc. Alteration Rights Reserved. 1/16, 9/2020

Before installation, read the following 

instructions carefully. Failure to follow 

instruction and Safety information could cause 

serious bodily injury, death and/or property 

damage. Each Power-Flo pump is individually 

factory tested to insure proper performance. 

Closely following these instructions will 

eliminate potential operating problems, 

assuring years of trouble-free service.

 

 

 Installation, wiring,

 

 

 and junction 

connections must be in accordance with 

the National Electric Code and all applicable 

state and local codes. Requirements may vary 

depending on usage and location.

 

 

  Installation and

 

 

   servicing is to be 

conducted by qualified personnel only.

 

 

  This pump is 

not

 

 

   intended for use in 

 swimming pools, spa areas or water 

 installations where human contact 

 with pumped fluid. 

 

 

 Risk of electric shock. 

 

 

  To reduce risk of 

  electric shock, always disconnect 

  pump from power source before 

  handling. 

Lock out power & tag.

  In the event the 

  retaining screws have

  been pulled out of the housing, 

  

DO NOT

 replace them. Use of any 

  other screw may short out the stator 

windings, creating a risk of electrical shock.

  The addition of 

  petroleum based fluids 

or certain chemical additives to the system 

voids the warranty.

 Pumps build up heat 

 and pressure during

 operation. Allow time

 for pumps to cool 

 before handling or

 servicing. 

Features:

These Power-Flo Pumps Circulator Pumps 

designed to be installed in residential potable 

domestic hot water systems to provide 

recirculation 

(with a dedicated recirculation 

pipe loop installed in the system)

 of domestic 

hot water resulting in “instant” hot water at 

fixtures throughout the house. This pump 

will come equipped with a standard terminal 

box to allow for connection to direct 115V AC 

wiring AND will come with a 6 Ft. long soft 

jacketed 3 prong electric cord and terminal 

box strain relief connector for “outlet plug in” 

installations.

NOTE: Model PFFP Cooper Multi Fitting 

Pack is to be used with the PFWRC66B1S 

circulator pumps.

 MOTOR: 

2-pole, 3600rpm, single phase,  

 

PSC with Thermal protection

 LIQUID TEMPERATURE: 

32°F - 230°F

 MAX. SYSTEM PRESSURE: 

145 PSI

 INSULATION: 

Class H

 VOLUTE: 

 Lead Free Bronze

 CONNECTION: 

 3/4” Copper Sweat

 POWER CORD: 

6 Foot with 3 prong plug

 ACCESSORIES: 

PFFP- Fitting Pack,  

PFDT - Digital Timer,  PFSOA - Snap-On 

Aquastat, PFRFV - Retro-Fit Valve

 WARRANTY: 

3 year

Receiving Inspection

Upon receiving the pump, it should be 

inspected for damage or shortages.   If 

damage has occurred, file a claim 

immediately with the company that delivered 

the pump. Care should be taken to ensure 

the pump is 

NOT

 dropped or mishandled, 

dropping will damage the pump. If the 

manual is removed from the packaging, do 

not lose or misplace.

WARNING: 

CANCER AND REPRODUCTIVE HARM-

WWW.P65WARNINGS.CA.GOV

Содержание PFWRC66B1S

Страница 1: ...werflopumps com ISP No PFCirc66B1S 9 2020 OWNER S MANUAL PFWRC66B1S Wet Rotor Circulator Pumps For Indoor Use Only Maintenance Free Power Flo Pumps Systems Your Power Ful partner for all your pumping...

Страница 2: ...or certain chemical additives to the system voids the warranty Pumps build up heat and pressure during operation Allow time for pumps to cool before handling or servicing Features These Power Flo Pump...

Страница 3: ...otor Ciculator Shut Off Head ft Max Flow Gal C Cast Iron B Lead Free Bronze S Stainless Steel 1 115 V 2 230V 1P F Flanged S Copper Sweat U Union EXAMPLE PFWRC2120C1F Power FloPumps WetRotorCirculator...

Страница 4: ...t Pressure ft 5 4 5 3 psi 2 2 1 9 1 3 In a pressurized system the required inlet pressure is the minimum allowable system pressure In a system open to the atmosphere the required inlet pressure is the...

Страница 5: ...rical This pump will come equipped with a 6 Ft long soft jacketed 3 prong electric cord and strain relief connection for outlet plug in installations The pump must be within 6 foot of a 115 volt recep...

Страница 6: ...culator Pumps Figure 2 Hot Water Line Cold Water Line PFWRC66B1S Circulator Pump ONLY Hot Water Tank Remove Drain valve from Hot Water Tank insert a tee and reinstall drain valve into tee Insert a tee...

Страница 7: ...or pump is then plugged into the timer allowing for time control of the pump This unit has an internal battery backup which will in the event of loss of AC power power the unit and save maintain progr...

Страница 8: ...including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels or feminine...