background image

8

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

IMPORTANT ! -

 The overload will then 

automatically reset and start the pump 
up after the motor cools to a safe 
temperature. In the event of an overload, 
the source of this condition should be 
determined and corrected immediately. 

 WARNING! - DO NOT LET
 THE PUMP CYCLE OR RUN IF
 AN OVERLOAD CONDITION 
 OCCURS !

If current through the temperature sensor 

exceeds the values listed, an intermediate 

control circuit relay must be used to 

reduce the current or the sensor will not 

work properly.

TEMPERATURE SENSOR ELECTRICAL 

RATINGS

Volts

Continuous

Amperes

Inrush

Amperes

110-120

3.00

30.0

220-240

1.50

15.0

440-480

0.75

7.5

600

0.60

6.0

Wire Size:
If longer power cable is required consult 
a qualified electrician for proper wire 
size.

Pre-Operation

1.   Check Voltage and Phase - Compare 
 

the voltage and phase information 

 

stamped on the pump name plate.

2.    Check Pump Rotation - Improper 

 

motor rotation can result in poor 

 

pump performance and can damage

 

the motor and/or pump. Check 

 

rotation on three phase units by 

 

momentarily applying power and 

 

observe the “kickback”.  

 

Kickback should always be in a 

 

counter-clockwise direction as 

 

viewed from 

motor end

 or 

opposite

 

 

to impeller rotation. Impeller rotation

 

is counter-clockwise as viewed from

 

bottom of pump.

3.    Name Plate - Record the information
 

from the pump name plate to 

 

drawing in front of manual for future 

 

reference.

4.   Insulation Test - An insulation 
 

(megger) test should be performed 

 

on the motor.  Before the pump is put 

 

into service. The resistance values 

 

(ohms) as well as the voltage (volts) 

 

and current (amps) should be 

 

recorded.

5.   Pump-Down Test - Be sure pump 
 

has been properly wired, lowered into 

 

the basin, sump or lift station, check 

 

the system by filling with liquid and 

 

allowing the pump to operate through

 

its pumping cycle. The time needed to

 

empty the system, or pump-down 

 

time along with the volume of water, 

 

should be recorded.

Maintenance

No lubrication or maintenance is required. 
Perform the following checks when  pump 
is removed from operation or when pump 
performance deteriorates:

a).   Inspect motor chamber for oil level 
 

and contamination.

b).  Inspect impeller and body for 
 

excessive build-up or clogging.

c).  Inspect motor, bearings and shaft seal
 

for wear or leakage.

Servicing

NOTE: Item numbers in ( ) refer to Figures 

6 through 10.

Cooling Oil - Anytime the pump is 

removed from operation, the cooling oil 

in the motor housing should be checked 

visually for oil level and contamination.

To check oil, set unit upright. Remove 

pipe plug (20) from housing (4).  With a 

flashlight, visually inspect the oil in the 

housing (4) to make sure it is clean and 

clear, light amber in color and free from 

suspended particles. Milky white oil 

indicates the presence of water. Oil level 

should be just above the motor when 

pump is in vertical position.

Oil Testing

•  Drain oil into a clean, dry container by

  placing pump on it’s side, remove pipe 

  plug (20), from housing (4). 
•  Check oil for contamination using an 

  oil tester with a range to 30 Kilovolts 

  breakdown.
•  If oil is found to be clean and 

  uncontaminated (measuring above 

  15 KV. breakdown), refill the housing.
•  If oil is found to be dirty or 

  contaminated (or measures below 

  15 KV. breakdown), the pump must 

  be carefully inspected for leaks at the 

  shaft seal, cable assembly, square ring 

  and pipe plug, before refilling with oil. To

  locate the leak, perform a pressure test.

After leak is repaired, dispose of old oil 

properly, and refill with new oil.

Installation & Service

PF4NC-SS   

 

 

 

 

 

 

 

 

      Non-Clog Pumps

Содержание PF4NC2824SS Series

Страница 1: ...SERVICE PARTS MANUAL Series PF4NC2824SS PF4NC2834SS PF4NC2844SS PF4NC3724SS PF4NC3734SS PF4NC3744SS PF4NC3764SS PF4NC5024SS PF4NC5034SS PF4NC5044SS PF4NC5064SS 2 8 3 7 5HP 1750RPM 60Hz Submersible Non...

Страница 2: ...and discharge openings Do not insert fingers in pump with power connected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps bu...

Страница 3: ...Filled reservoir with Secondary Exclusion seal Silicon Carbide Buna N UPPER BEARING Single row ball oil lubricated LOWER BEARING Single row ball oil lubricated POWER CORD 25 Ft Cord Epoxy sealed housi...

Страница 4: ...umps Systems 877 24PUMPS www powerflopumps com Dimensions PF4NC2824SS PF4NC3724SS PF4NC3734SS PF4NC3744SS PF4NC3764SS PF4NC5024SS PF4NC5034SS PF4NC5044SS PF4NC5064SS PF4NC2834SS PF4NC2844SS PF4NC SS N...

Страница 5: ...W 0 75 PF4NC3724SS 3 7 60 230 1 1750 A 18 5 29 0 10 3 SOW 0 69 PF4NC3734SS 3 7 60 230 3 1750 F 14 0 50 8 10 4 SOW 0 75 PF4NC3744SS 3 7 60 460 3 1750 F 7 0 25 4 10 4 SOW 0 75 PF4NC3764SS 3 7 60 208 3 1...

Страница 6: ...6 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF4NC SS Non Clog Pumps...

Страница 7: ...ws the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor Discharge Piping Discharge piping should be as short as possible and sized no sm...

Страница 8: ...ump has been properly wired lowered into the basin sump or lift station check the system by lling with liquid and allowing the pump to operate through its pumping cycle The time needed to empty the sy...

Страница 9: ...ooling Oil Recommended Supplier Grade BP Enerpar SE100 Conoco Pale Paraf n 22 Mobile D T E Oil Light Shell Canada Transformer 10 Texaco Diala Oil AX Disassembly Impeller andVolute 1 Disconnect power 2...

Страница 10: ...otating member and not cocked or resting on bellows tail Bearing Motor 6 Slide rotor shaft with bearing 8 and seal parts 6 into seal plate 3 until bearing seats into seal plate and tighten conduit bus...

Страница 11: ...4 and gland nut 23 into motor housing 4 or conduit box cable assembly 33 and torque gland nut 23 to 15 ft lbs 19 on models PF4NC2834SS 2844SS 2854SS refill with with cooling oil and replace pipe plug...

Страница 12: ...77 24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 6 PF4NC2...

Страница 13: ...77 24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 7 PF4NC2...

Страница 14: ...F92010083 19 1 O ring PF92010082 20 1 Pipe Plug 3 4 NPT 21 1 Eye Bolt 1 2 13 x 1 Lg Power Cable Assy Includes 22 23 24 25 PF053165 22 1 Power Cable 25 Ft 10 4 SOW PF31030003 23 1 Gland Nut PF30400903...

Страница 15: ...werflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 8 PF4NC2824SS 3724SS 3734...

Страница 16: ...24PUMPS www powerflopumps com Parts List For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 9 PF4NC2824S...

Страница 17: ...1 V Gasket PF92010112 17 2 Soc Hd Cap Screw 1 4 20 x 1 Lg Stainless 18 1 O ring PF92010083 19 1 O ring PF92010082 20 1 Pipe Plug 3 4 NPT 21 1 Eye Bolt 1 2 13 x 1 Lg Power Cable Assy Includes 22 23 24...

Страница 18: ...w powerflopumps com Parts List For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 10 PF4NC3734SS 3744SS 3...

Страница 19: ...F91010111 15 1 Washer Impeller PF91010051 16 1 V Gasket PF92010112 17 2 Soc Hd Cap Screw 1 4 20 x 1 Lg Stainless 18 1 O ring PF92010083 19 1 O ring PF92010082 20 1 Pipe Plug 3 4 NPT 21 1 Eye Bolt 1 2...

Страница 20: ...On Part Numbers 33 1 Conduit Box PF03100010 35 1 O ring PF92010063 36 4 Cap screw 1 4 20 x 1 Lg Stainless 37 4 Lockwasher 1 4 Stainless 38 6 Female Connector PF94010041 39 1 85gal Cooling Oil Aquire l...

Страница 21: ...21 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Notes PF4NC SS Non Clog Pumps...

Страница 22: ...22 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Notes PF4NC SS Non Clog Pumps...

Страница 23: ...phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits and fluid temperature 13 Repla...

Страница 24: ...not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand grave...

Отзывы: