V 4.0
18 Gauge In-Line Air Shear
8654568
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not function
properly or parts are missing. If unable to do so, have a qualified technician
service the tool.
Problems
Possible Causes
Suggested Solutions
Tool runs at normal
speed, but loses
power under load.
Motor parts worn.
1. Have a qualified technician service
the tool.
2. Replace tool or parts.
Tool runs slowly.
Air flows slightly
from exhaust.
Motor parts jammed
with dirt particles.
OR
Airflow blocked by dirt.
1. Check air inlet filter for blockage.
2. Pour air tool lubricating oil into air
inlet as per lubrication instructions for
clearing shipping grease.
3. Operate tool in short bursts to clear
debris.
4. If tool still jammed, clean tool and
lubricate per lubrication instructions.
Air regulator in closed
position.
Open the air regulator to desired
airflow.
Tools will not run.
Air flows freely
from exhaust.
Damage or excessive
wearing of internal
parts.
1. Have a qualified technician service
the tool.
2. Replace tool or parts.
Tool will not shut
off.
1. Throttle valve o-ring
dislodged from seat
inlet valve.
2. Trigger mechanism
jammed or dirty.
1. Replace throttle valve o-rings.
2. Clean trigger mechanism and
lubricate.
Loss of power or
erratic
performance.
Excessive drain on the
air hose. Incorrect size
or type of hose
connectors.
Check the air hose and confirm the
hose fitting is correct for the inlet
bushing.
Moisture or restriction
in the air hose/tank
Depressurize system and drain tank
and air hose of water.
Air compressor has
insufficient flow.
Ensure tool is connected to a
compressor with a rate flow that
matches the tool.
Visit www.princessauto.com for more information
11