background image

Visitez www.princessauto.com pour plus d'informations 

7

8519209 

V 3,04

Pompe pour eaux usées en acier inoxydable de 1/2 CV

TESTING

NOTE: 

When the pump is installed in a basin with a sealed cover, you cannot observe the operation of 

the float switch. The cover usually will have a spare hole that is blocked with a rubber plug. Remove 

this plug to observe the switch operation during testing.

1.  Check the pump label for proper voltage required.

 

WARNING! Do not connect to a voltage other than that shown.

2.  Plug the power cord directly into a GFCI equipped electrical outlet.

3.  Run water into the basin until the pump starts.

4.  Be sure the check valve in the discharge line is open.

5.  Allow the pump to operate through several on / off cycles.

MAINTENANCE

1.  Cycle the pump at least once every month to be sure that the system is working properly.

2.  Before removing the pump from the basin for service, always disconnect the electrical power 

source to the pump and the control switch. Do not lift the pump by the power cord.

WARNING! Sudden starts. If the power is on to the pump when the thermal overload resets, the 

pump may start without warning. If you are working on the pump, you may get an electrical shock 

or the impeller may catch fingers or tools.
WARNING! Disconnect the pump from the power source before servicing.
NOTE: 

This pump has no serviceable parts. The motor housing of the pump is completely sealed and 

requires no service. Disassembly of the motor housing or alteration of the power cord will void all 

warranties. The power cord on this pump cannot be replaced. If it becomes damaged, the entire pump 

must be replaced.

DISINFECT THE PUMP

Place the pump in an area where it can be cleaned thoroughly. Remove all scale and deposits on  

the pump.

NOTE: 

Wear rubber or plastic gloves when handling the pump for service. Completely submerge the 

pump in a disinfectant solution (Clorox or chlorine bleach) for at least one hour before disassembling 

the pump.

LUBRICATION

The pump is permanently lubricated. No oiling or greasing is required in normal operation.

Содержание 8519209

Страница 1: ...User Manual V 3 04 8519209 Please read and understand all instructions before use Retain this manual for future reference 1 2 HP Stainless Steel Sewage Pump...

Страница 2: ...1 300 gallons per hour Flow Rate 20 Feet 700 gallons per hour Float Switch Vertical Cord Length 10 feet CUL CUL 248578 IMPORTANT SAFETY PRECAUTIONS WARNING Read and understand all instructions before...

Страница 3: ...otwear are recommended when working Wear steel toed boots to prevent injury from falling objects 2 Control the tool personal movement and the work environment to avoid personal injury or damage to the...

Страница 4: ...prevent pumping and or damage the motor 4 Do not handle or service the pump while it is connected to the power supply 5 Do not remove the grounding prong from the plug or modify the plug To protect a...

Страница 5: ...CAUTION The motor housing transfers heat to the volute This pump is capable of operating with the motor housing partially exposed for extended periods while still providing sufficient motor cooling an...

Страница 6: ...2 HP Stainless Steel Sewage Pump 6 For technical questions call 1 800 665 8685 V 3 04 8519209 Pump on level 7 to 8 in 18 cm to 20 32 cm Pump off level 4 to 5 in 10 cm to 13 cm TYPICAL INSTALLATION Fig...

Страница 7: ...l power source to the pump and the control switch Do not lift the pump by the power cord WARNING Sudden starts If the power is on to the pump when the thermal overload resets the pump may start withou...

Страница 8: ...ump does not turn on The pump is not plugged in Plug in the pump Circuit breaker shutoff or the fuse is removed Turn on the circuit breaker or replace the fuse Accumulation of buildup on the float Cle...

Страница 9: ...mp from service and clean The pump is air locked Shut the power off for approximately 1 minute then restart the pump Repeat several times to clear the air from the pump The pump does not deliver the r...

Страница 10: ......

Страница 11: ...e et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Manuel d utilisateur V 3 04 8519209 Pompe pour eaux us es en acier inoxyd...

Страница 12: ...dable Mat riau d impulseur Fonte D bit 5 pi 2 500 gal h D bit 10 pi 2 000 gal h D bit 15 pi 1 300 gal h D bit 20 pi 700 gal h Interrupteur flotteur Vertical Longueur du cordon 10 pi CUL CUL 248578 CON...

Страница 13: ...protection Utilisez des protections pour les voies respiratoires les oreilles les yeux le visage les pieds les mains et la t te Portez toujours des lunettes de s curit tanches approuv es par l ANSI q...

Страница 14: ...est identique 14 N exposez pas la pompe aux temp ratures de cong lation Le gel pourrait causer des dommages graves ce qui annulera la garantie 15 N introduisez pas de doigt ou d objet dans les orifice...

Страница 15: ...n pr sence d quipement lectrique vitez que le corps entre en contact avec des surfaces mises la terre Il y a un risque plus lev de choc lectrique si votre corps est mis la terre AVERTISSEMENT Un lectr...

Страница 16: ...UE Ne placez jamais la pompe directement sur des surfaces d argile de terre ou de gravier 2 Installez la pompe au moyen d un tuyau en ABS en PVC en poly thyl ne ou en acier galvanis Utilisez les bons...

Страница 17: ...un couvercle scell vous ne pouvez observer le fonctionnement de l interrupteur flotteur Ce couvercle pr sentera habituellement un orifice de r serve qui est bouch au moyen d un bouchon de caoutchouc E...

Страница 18: ...mpe de la source d nergie avant de proc der l entretien REMARQUE Cette pompe n est munie d aucune pi ce dont on peut proc der l entretien Le carter de moteur de la pompe est compl tement scell et ne d...

Страница 19: ...pendant environ 1 minute et red marrez ensuite la pompe Recommencez plusieurs reprises afin d vacuer l air de la pompe L arriv e de liquide a atteint la capacit de la pompe Une pompe de capacit sup ri...

Страница 20: ...r vous assurer qu elle correspond la tension indiqu e sur la plaque signal tique Le centrifugeur ou le tuyau de refoulement est ferm Enlevez la pompe afin de proc der son entretien et son nettoyage La...

Отзывы: