PREPARATION FOR INSTALLING THE EQUIPMENT
For proper inspection and ventilation, as well as correct handling, it is important to leave clearance
around the equipment. The following image shows the recommended minimum distances:
Side to side distance:
Front side distance:
For the working or maintenance moments in the charger, it requires 1m free of
obstacles in front of the door, which allows open the door completely and work fluently.
Rear side distance:
It does not require a special rear space; it can be installed in touch with a wall or
other element.
The minimum distance between chargers is shown above. However, the distance between parking
spaces must be also considered since the user should be able to maneuver the hose between two cars.
The maximum length reached by the charging hose should also be taken into account.
Maximum hose range
When installing the equipment Please note that the charger has two hoses, one on each side. Therefore,
the maximum range of the cables will be equal on both sides. The hose range depends on the length
selected by the customer, the standard hose in IEC is 3m / 9.84ft straight cable, but other options are
available.
The following figure shows an example of the cable range area in a parking lot with the centralized pole:
Содержание NB CITY
Страница 1: ...NB CITY HARDWARE AND INSTALLATION MANUAL ELECTRICAL VEHICLES CHARGING SOLUTIONS...
Страница 2: ......
Страница 3: ...NB City EV CHARGING SOLUTIONS Hardware and Installation Manual Edition April 2020 NBCHW01CI Rev C...
Страница 45: ...CE_NB50_REV0_11122019 www power electronics com EN...
Страница 46: ...CE_NB50_REV0_11122019 www power electronics com...
Страница 47: ......
Страница 48: ...24H TECHNICAL ASSISTANCE 365 DAYS A YEAR FIND YOUR NEAREST DELEGATION POWER ELECTRONICS COM CONTACT...