- 22 -
0700_gb-Dosierer_548
GB
regulaTing rollers
Scraper floor switch
General
Where regulating rollers are built in, the screw (SK-5) is
situated behind the switch and has no function there.
The switch slider (90) is held in position
A
by means of a
component on the regulating roller.
The scraper floor drive can only be switched on as
follows:
- by means of the automatic loader
or
- by activating the scraper floor switch on the switch
console
Where regulating rollers have been dismantled, the switch
slider (90) would be in
position B
. In this position, the
scraper floor drive is constantly switched off. However this
is not required in the loading and unloading procedures.
Thus, where the regulating rollers have been dismantled,
the switch must be fixed in position
A
. This is achieved
by means of the bolt supplied (SK-5).
Setting when regulating rollers have been
dismantled
1. Push the switch slider (90) into position
A
2. Screw the bolt (SK-5) down in the elongated hole, so
that the switch slider (90) remains fixed in position
A
.
Installing an oil pressure switch
It is recommended that an oil pressure switch () be installed
when operating without regulating rollers.
When the load presses against the tailgate, the scraper
floor drive is automatically switched off by means of the
oil pressure switch.
The oil pressure switch has no function when regulating
rollers are installed.
- Electro-connection see spare parts list, circuit diagram
see supplement.
- For setting see chapter “MAINTENANCE”
001-01-34
A
SK-5
B
90
Note!
A greater injury
danger exists
when working
behind opened
protective covers.
220 - 230 bar