- 7 -
0701_GB-Power-control_5543
GB
PoWer conTrol - oPeraTion
Sensor test
The sensor test display can be reached from the WORK
or the DIAG mask by
- pressing the STOP button
for 4 secs.
Leave the test display by
- pressing the I/O button
Display of the present sensor conditions
Power take-off r.p.m. (Still stand)
Power take-off running (rpm >225)
Job calculator power supply
Minimum value since switching on
Actual value
level flap on top
level flap underneath
Cutting unit swung out
Pressure on dosing rollers
Tailgate open
Oil pressure switch
Example:
A black square near the symbol for level flap on top
means:
- Level flap is actuated.
- When activating and not activating the sensors, the
square must change between black and white.
Adjusting machines
The CONFIG display can be reached from the WORK or
the TEST mask by
- pressing the STOP button
for 8 secs.
The current configuration is given here first of all.
Automatic loading
Cross conveyor belt
Trailing front axle
Scraper floor stage 2
Regulating Rollers
Loading space lighting
A = Automatic
- Spotlight comes on when tailgate is open
M = Manual
Constant light if activated in SET
Menu
Forage reagent distributor
Forage top frame
- Further switching between the individual settings takes
place with the I/O key
.
- The selection arrow points to the each selected
setting.
- The function can be switched on or off using the
"+"
and "-"
keys.
Tick in front of symbol = function switched on
Cross in front of symbol = function switched off
Cross conveyor belt is the exception (cross = function
switched off, M = mechanical drive, H = hydraulic
drive).
- The display and control functions are adapted.
- The output diagnosis for unavailable functions is
deactivated.
Leaving the CONFIG mask is only possible by
- pressing the STOP button
- Job calculator sets back all output diagnosis
hindrances (RESET all diagnosis functions).
- Restart is carried out.