2. PROLONGED SHUTDOWN. FROST PROTECTION
Do not drain the whole system as filling up with water again could cause unnecessary and harmful scale to build up inside the
boiler and the heating elements. If the boiler is not used during winter and is therefore exposed to the danger of frost, add some
specific anti-freeze to the water in the system (e.g.: propylene glycol coupled with corrosion and scale inhibitors). The electronic
boiler management system includes a “frost protection” function for the heating system which, when delivery temperature falls
below 5°C, lights the burner until a delivery temperature of 30°C is reached.
The function is operative if: the boiler is electrically powered, there is gas, system pressure is normal and the boiler is not
blocked.
3. GAS CONVERSION
The boilers can operate both on natural gas (G20) and LPG (G31)
.
All gas conversions must be made by the AUTHORISED
TECHNICAL SERVICE CENTRE.
4. FAULTS
The faults shown on the display are identified with the symbol and a number (fault code). For a com-
plete list of faults, see the following table.
If appears on the display the fault must be RESET by the user.
To RESET the boiler, press
. If faults are displayed frequently, call the Authorised Service Engineer.
Description of fault
Description of fault
10
Outdoor temperature sensor faulty
128
No flame during normal operation
20
NTC flow sensor faulty
130
Fumes NTC tripped due to over temperature
28
NTC fumes sensor faulty
132
Gas pressure switch Safety shutdown.
40
NTC return sensor faulty
133
Ignition failure (4 attempts)
50
NTC domestic hot water sensor faulty
(only for heating-only model with storage tank)
151
Boiler board internal fault
83
Communication problem between boiler board and
control unit. Probable short circuit on wiring.
153
Hardware reset button pressed more than 10 seconds
84
Address conflict between control units
160
Fan fault
109
Air in boiler circuit (temporary fault)
164
Flow pressure switch faulty
110
Safety thermostat tripped due to over temperature.
(pump probably blocked or air in heating circuit)
384
Parasite flame (internal error)
111
Safety thermostat tripped due to overtemperature.
385
Input voltage too low
117
Pressure in hydraulic circuit too high
386
Fan speed threshold not reached
118
Pressure in hydraulic circuit too low
430
No circulation safety trip
(control performed via pressure sensor)
125
No circulation safety trip
(control performed via a temperature sensor)
432
No functional hearth or safety thermostat tripped due to over
temperature (E110)
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.
5. BOILER INFORMATION MENU
Press
to display the information indicated in the following table. Press
to exit.
Description
Description
00
SW Diagnostic Code
11
Ion current
01
Heating flow temperature
12
Burner working hours
02
Outdoor temperature (if the outdoor sensor is fitted)
13
Zone 2 heating flow temperature
03
External storage tank temperature (fitted models)
14
Zone 1 heating mode
04
Storage tank temperature (fitted models)
15
Zone 2 heating mode
05
Water pressure in heating system
16
DHW circuit operating mode
06
Heating return temperature
17
Boiler operating mode
07
Flue sensor temperature
18
Solar plant operating mode
08
Not used
19
Manufacturer information
10
Zone 1 heating flow temperature
20
Manufacturer information
Содержание Sirius two WH
Страница 21: ...21 I N S T A L L E R S e c t i o n e n 7108686 02 1 11 12 ...
Страница 25: ...25 S E C T I O N C 7108686 02 1 11 12 ...
Страница 28: ...7108686 02 1 11 12 28 S E C T I O N F WEATHER COMPENSATION CURVE GRAPHS QAC34 ...
Страница 29: ...29 S E C T I O N G 7108686 02 1 11 12 AGU 2 550 CR_0349 CR_0349 AVS 75 ...
Страница 30: ...7108686 02 1 11 12 30 S E C T I O N G CG_2482 SAFETY THERMOSTAT Tmax 50 C free contact ...
Страница 31: ...31 7108686 02 1 11 12 MODIFIED PARAMETERS Nr VALUE NOTE ...