GENERAL PRECAUTIONS 

This boiler has been designed to heat water to a temperature lower than boiling point at atmospheric pressure. It must be connec-

ted to a central heating system and to a domestic hot water supply system according to its performance and power output. Before 

having the boiler installed by a qualified service engineer, make sure the following operations are performed:

  

•  Make sure that the boiler is adjusted to use the type of gas delivered by the gas supply. To do this, check the markings on the 

packaging and the rating plate on the appliance.

•  Make sure that the flue terminal draft is appropriate, that the terminal is not obstructed and that no exhaust gases from other 

appliances are expelled through the same flue duct, unless the latter has been specially designed to collect exhaust gas from 

more than one appliance, in compliance with current laws and regulations.

•  Make sure that, if the boiler is connected to existing flue ducts, these have been thoroughly cleaned as residual products of 

combustion may detach from the walls during operation and obstruct the flow of fumes.

•  The use of a chimney liner is required for condensing boiler.

•  To ensure correct operation and maintain the warranty, observe the following precautions:

  

1.   DHW circuit

 

 

1.1

 If the water is harder than 15 °F (1 °F = 10 mg calcium carbonate per litre of water), install a polyphosphate dispenser or an 

equivalent treatment system, compliant with current regulations.

1.2

 Thoroughly flush the system after installation of the appliance and before use.

1.3

 The materials used for the DHW circuit must comply with Directive 98/83/EC.

  

2. Heating circuit

  

2.1 New system

: Before installing the boiler, the system must be cleaned and flushed to eliminate residual thread-cutting swarf, 

solder and any solvents, using suitable off-the-shelf non-acid and non-alkaline products that do not damage metal, plastic and 

rubber parts. To protect the system from scale, use inhibitors such as SENTINEL X100 and FERNOX protector for heating circuits. 

Use these products in strict compliance with the manufacturers’ instructions.

 

   

2.2 Existing system

: Before installing the boiler, drain the system and clean it to remove sludge and contaminants, using suitable 

proprietary products. Recommended cleaning products are: SENTINEL X300 or X400 and FERNOX regenerator for heating cir-

cuits. Use these products in strict compliance with the manufacturers’ instructions. Remember that the presence of foreign bodies 

in the heating system can adversely affect boiler operation (e.g. overheating and excessive noise of the heat exchanger).

  

Initial lighting of the boiler must be carried out by an authorised Service Engineer who must first ensure that:

  

•  The rated data correspond to the supply (electricity, water and gas) data.

•  That the installation complies with current regulations.

•  The appliance is correctly connected to the power supply and earthed.

 

  

IMPORTANT INFORMATION : DO NOT FIRE THE BOILER COMMISSIONING IF USED ON LPG (G31)

  

 

The appliance must be installed in a ventilated boiler room pursuant to current regulations (appliances with heating capacity 

> 40 kW). 

  

Failure to observe the above will render the warranty null and void. The names of the authorised Service Centres are indica-

ted in the attached sheet. Prior to commissioning, remove the protective plastic coating from the boiler. Do not use any tools 

or abrasive detergents to do this as you may damage the painted surfaces.

Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of danger.

  

ENERGY-SAVING TIPS

Adjustment in the heating mode

  

Adjust the boiler flow temperature depending on the kind of system. For systems with radiators, set a maximum heating water flow 

temperature of approximately 60°C, and increase this value if the required room temperature is not reached. For systems with 

radiant floor panels, do not exceed the temperature indicated by the system designer. Use the External Sensor and/or Control 

Panel to automatically adjust the flow temperature to atmospheric conditions or the indoor temperature. This ensures that no more 

heat than that effectively necessary is produced. Adjust the room temperature without overheating the rooms. Every extra degree 

centigrade means consuming approximately 6% more energy. Also room ambient temperature depending on how the rooms are 

used. For example, the bedroom or the least used rooms can be heated to a lower temperature. Use the programmable timer and 

set the night-time room temperature at approximately 5°C lower than that during the day. There is no appreciable saving to be 

achieved by setting it any lower. Only in case of a prolonged absence, such as a holiday, should the temperature setpoint be lowe-

red. Do not cover radiators as this prevents the air from circulating correctly. Do not leave the windows partially open to ventilate 

the rooms but open them completely for a short period.

 

 

 

Domestic hot water

  

 

 

Setting the domestic hot water at the required temperature without mixing it with cold water saves a lot of money. Additional hea-

ting wastes energy and creates additional scale. Recommended minimum storage temperature of 60°C to reduce the Legionella 

risk.

 

Содержание Sirius two WH

Страница 1: ...Working towards a cleaner future Sirius two WH 90 110 kW Instruction manual for users and fitters To be kept by the user November 2013 heating specialists ...

Страница 2: ...N OF SYMBOLS 3 SAFETY WARNINGS 3 GENERAL PRECAUTIONS 4 ENERGY SAVING TIPS 4 1 COMMISSIONING THE BOILER 5 1 1 ADJUSTING THE CH AND DHW FLOW TEMPERATURE 5 1 2 OPERATING MODES 5 2 PROLONGED SHUTDOWN FROST PROTECTION 6 3 GAS CONVERSION 6 4 FAULTS 6 5 BOILER INFORMATION MENU 6 6 FILLING THE SYSTEM 7 7 ROUTINE MAINTENANCE INSTRUCTIONS 7 8 SWITCHING OFF THE BOILER 7 INSTRUCTIONS PRIOR TO INSTALLATION 8 9...

Страница 3: ...ymbol SAFETY WARNINGS SMELL OF GAS Switch off the boiler Do not activate any electrical device such as switching on the light Put out any naked flames and open the windows Call an Authorised Service Engineer SMELL OF COMBUSTION FUMES Switch off the boiler Open all the doors and windows to ventilate the room Call an Authorised Service Engineer FLAMMABLE MATERIAL Do not use and or store highly flamm...

Страница 4: ...e heating system can adversely affect boiler operation e g overheating and excessive noise of the heat exchanger Initial lighting of the boiler must be carried out by an authorised Service Engineer who must first ensure that The rated data correspond to the supply electricity water and gas data That the installation complies with current regulations The appliance is correctly connected to the powe...

Страница 5: ...ater pressure low Heating mode enabled Technical Service Centre call in Programming menu Manually resettable fault Boiler information menu Fault in progress Set unit of measurement SI US 1 1 ADJUSTING THE CH AND DHW FLOW TEMPERATURE Press and respectively to adjust the CH and DHW flow temperature if an external storage tank is fitted When the burner is lit the display shows the symbol HEATING whil...

Страница 6: ...g only model with storage tank 151 Boiler board internal fault 83 Communication problem between boiler board and control unit Probable short circuit on wiring 153 Hardware reset button pressed more than 10 seconds 84 Address conflict between control units 160 Fan fault 109 Air in boiler circuit temporary fault 164 Flow pressure switch faulty 110 Safety thermostat tripped due to over temperature pu...

Страница 7: ... is no water If pressure drops occur frequently monthy basis have the system checked by the AUTHORISED TECHNICAL SERVICE CENTRE 7 ROUTINE MAINTENANCE INSTRUCTIONS To keep the boiler efficient and safe have it checked by the Authorised Service Centre at the end of every 12 months Careful servicing ensures economical operation of the system 8 SWITCHING OFF THE BOILER To turn off the boiler disconnec...

Страница 8: ...ting system installing a new system as well as the above fit a strainer under the boiler on the system return line in order to collect any deposits and scale circulating in the system after flushing After fixing the boiler to the template connect the flue and air ducts supplied as accessories as described in the following sections Connect the siphon to a drain trap making sure the slope is continu...

Страница 9: ...sed to discharge exhaust fumes and draw combustion air both outside the building The 87 concentric bend allows the boiler to be connected to a flue air in any di rection as it can be rotated by 360 It can also be used as a supplementary curve combined with a concentric flue or a 45 bend If fumes are discharged outside the building the flue air must protrude at least 200 mm from the wall to allow a...

Страница 10: ... high voltage 230 V Before making connections make sure the appliance is disconnected from the power supply Check the input polarity on terminal block M1 L LINE N NEUTRAL TERMINAL BLOCK M1 L Live brown N Neutral light blue Earth yellow green 1 2 contact for Room Thermostat Put back the jumper on terminals 1 2 of boiler terminal block M1 if the room thermostat is not used or if the Remote Control i...

Страница 11: ...ounting and operation instructions supplied with the kit A Proceed as follows Switch off the boiler Pass the three wires from the boiler terminal block M2 through the hole in the base A1 to apply to the wall Connect wires 1 2 3 of the boiler terminal block M2 to terminals 1 2 3 of the base terminal block A1 respectively Fix the base A1 to the wall using the expansion grips and screws supplied with...

Страница 12: ...e new configuration Access menu 2 as indicated at the beginning of this section B Configuration B B programme row 6200 then B B Yes then B to confirm ZONE SYSTEM WITH INSTALLATION OF THE REMOTE CONTROL The electrical connection and the adjustments required to manage a system divided into zones with use of the Remote Control differs according on the accessories connected to the boiler To install an...

Страница 13: ...d connect it to terminals 9 10 of terminal block M2 see annex SECTION B Make sure that the exchange capacity of the domestic hot water coil is appropriate for the power of the boiler OUTDOOR SYSTEM MANAGEMENT MODULES The boiler can independently manage up to three heating circuits by using external accessories such as room units remote controls and external modules AVS 75 The boiler electronics al...

Страница 14: ...for high fire and 0 for low fire To exit press both buttons together for at least 6 seconds as described in point one Press to display the instantaneous flow temperature for 15 seconds 12 3 CHIMNEY SWEEP MODE When this function is enabled the boiler generates maximum heating power To enable the function proceed as follows press together for 6 seconds The display shows 303 alternated with the power...

Страница 15: ... if P23 1 7 1 7 1 daily 2 6 intervals of 2 6 days 7 once a week P25 1663 Circulation temperature setpoint additional DHW pump C 45 8 80 P26 5470 Preheating time for DHW circuit 1 10 144 1440 min 0 0 144 BOILER PARAMETERS P27 2243 Minimum boiler off time min 3 0 20 P28 2217 Frost Protection setpoint C 5 20 20 P29 2250 Pump post circulation time min 3 0 240 P30 2441 Max fan speed heating rpm xxx 0 8...

Страница 16: ...e flue duct with the boiler operating at minimum heat capacity matches that indicated in table 2 allowed tolerance 0 5 If it does not remove the threaded brass cap on the gas valve and turn the adjustment screw K Turn the screw clockwise to increase the level of and anticlockwise to decrease it allowed tolerance 0 2 15 1 GAS CONVERSION When converting from natural gas to propane LPG before calibra...

Страница 17: ...causes the main burner to go out Antifreeze device The electronic boiler management system includes an antifreeze function for the heating and DHW systems which when flow temperature falls below 5 C operates the burner until a flow temperature of 30 C is reached This function is enabled when the boiler is switched on the gas supply is open and the system is correctly pressurised Pump anti block fu...

Страница 18: ...semble the heat exchanger protect the electronic box and all the electrical components against sprayed water Proceed as follows to dismount the Heat Exchanger Isolate the unit from the electrical mains disconnect the boiler from the main elecrical supply Cut off the gas supply to the boiler Close the maintenance taps on the boiler Remove the front cover trom the boiler Unscrew the screw securing t...

Страница 19: ...iciency and the emissions of the products of combustion the boiler is fitted with two dedicated test points One connection point is connected to the flue gas discharge circuit A and allows monitoring of the quality of the combustion products and the combustion efficiency The other is connected to the combustion air intake circuit B allowing checking of any recycling of the combustion products in c...

Страница 20: ... Capacity of boiler circuit volume of water l 9 10 Temperature range in heating circuit C 25 80 Flue Types C13 C33 B23 Concentric flue duct diameter mm 110 160 Diameter of separate outlets mm 110 110 Max mass flow rate of flue G20 kg s 0 040 0 047 Min mass flow rate of flue G20 kg s 0 005 0 005 Max temperature of fumes C 70 NOx Class 5 EN 297 EN 483 mg kWh 39 5 24 7 Natural gas supply pressure 2H ...

Страница 21: ...21 I N S T A L L E R S e c t i o n e n 7108686 02 1 11 12 ...

Страница 22: ...and return 9 Safety overflow temperature thermostat 10 Flame detection electrode 11 Spark generator 12 Venturi 13 Pump 14 Hydraulic Safety valve 15 Boiler drain tap 16 Pressure gauge 17 Hydraulic Pressure Sensor 18 Gas pressure switch 19 Gas valve A Trap condensate drain B Gas inlet connection C Heating flow connection D Heating return connection 1 A B C D 2 3 5 4 6 8 16 9 7 14 10 12 13 15 18 17 1...

Страница 23: ...3 L N L N 230 V 230 V 13 13 V N N R M C C M V N N R C C C M 12 11 10 9 8 7 6 5 4 3 2 1 N V R C C R R G V G V Y P N M 1 Fuses 2 230 V Power Supply 3 Room Unit RU 4 Heating flow sensor 5 Heating return sensor 6 Water pressure switch 7 Fumes sensor 8 DHW tank sensor 9 Auxiliary Sensor 1 10 Auxiliary Sensor 2 11 Outdoor sensor 12 Remote Control 13 Boiler pump 14 Flame sensor electrode 15 Ignition elec...

Страница 24: ...8686 02 1 11 12 24 S E C T I O N C 7109986 01 G1 1 2 G1 1 2 G1 G 1 G1 1 2 198 100 100 100 102 90 5 419 90 5 600 30 245 5 951 809 50 70 72 584 600 112 354 5 245 5 952 112 170 184 5 245 5 G1 1 2 Ø 8 Ø 8 Ø 8 ...

Страница 25: ...25 S E C T I O N C 7108686 02 1 11 12 ...

Страница 26: ...7108686 02 1 11 12 26 S E C T I O N D A B Lmax 10 m Ø 110 160 mm C D Lmax 9 m Ø 110 160 mm E F Lmax 10 m Ø 110 160 mm G Lmax 8 m Ø 110 160 mm H Lmax 9 m Ø 110 160 mm ...

Страница 27: ... l h WH 90 WH 110 0 1 2 3 4 5 6 7 8 0 4 0 0 8 0 0 1 2 0 0 1 6 0 0 2 0 0 0 2 4 0 0 2 8 0 0 3 2 0 0 3 6 0 0 4 0 0 0 4 4 0 0 Q l h H mH 2 O 0 1 2 3 4 5 6 7 8 0 4 0 0 8 0 0 1 2 0 0 1 6 0 0 2 0 0 0 2 4 0 0 2 8 0 0 3 2 0 0 3 6 0 0 4 0 0 0 4 4 0 0 4 8 0 0 Q l h H mH 2 O WH 90 WH 110 ...

Страница 28: ...7108686 02 1 11 12 28 S E C T I O N F WEATHER COMPENSATION CURVE GRAPHS QAC34 ...

Страница 29: ...29 S E C T I O N G 7108686 02 1 11 12 AGU 2 550 CR_0349 CR_0349 AVS 75 ...

Страница 30: ...7108686 02 1 11 12 30 S E C T I O N G CG_2482 SAFETY THERMOSTAT Tmax 50 C free contact ...

Страница 31: ...31 7108686 02 1 11 12 MODIFIED PARAMETERS Nr VALUE NOTE ...

Страница 32: ...NOV2013 Baxi Commercial Wood Lane Erdington Birmingham B24 9QP Email potterton commercial baxicommercialdivision com www pottertoncommercial co uk heating specialists Sales 0845 070 1056 Technical 0845 070 1057 RS 33961 ...

Отзывы: