![Potterton SIRIUS THREE FS 130 Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/potterton/sirius-three-fs-130/sirius-three-fs-130_installation-user-and-service-manual_1583142096.webp)
Parameter
number
Parameter
Description
Factory set
ting
7146
Deaeration function
Venting function:
Off
On
Off
7147
Type of venting
Venting cycle operating mode:
None
Heating circuit continuous
Heating circuit cycled
Hot water continuous
Hot water cycled
None
7170
Telephone customer
service
7231
Refill time current
week
Value displayed
0 s
7232
Refill time to date
Value displayed
0 s
7233
Number of refills to
date
Value displayed
0
Tab.57 State menu
Parameter num
ber
Parameter
Description
8000
State central heating
CH1
8001
State central heating
CH2
8002
State central heating
CH3
8003
State hot water
8005
State boiler
8007
State solar
8008
State solid fuel boiler
8009
State burner
8010
State buffer
8011
State swimming pool
Tab.58 Diagnostics heat generation menus
Parameter num
ber
Parameter
Description
8310
Boiler temperature
Control temp
Value displayed
8311
Boiler setpoint
Control setpoint
8313
Control sensor
8314
Boiler return temp
8315
Boiler return temp
setpoint
8316
Flue gas temp
8321
Primary exchanger temp
8323
Fan speed
8326
Burner modulation
10 Settings
96
7702639 - v03 - 10072018