28
8-card Shelf CCC model 751109/15
Figure 2: Shelf Ground Connections: Side View
The LED indicates the presence of -24 Vdc or -48 Vdc in the shelf, regardless of
the source from an external or an internal power supply. The 5 A, 125 Vac, fast-
blow, replaceable fuse protects the internal power supply (if installed) from
excessive currents or overvoltage.
When powered through an external source, the requirements are:
Q
-24 Vdc -21 Vdc to -27 Vdc, 3A
Q
-48 Vdc -42 Vdc to -54 Vdc, 2A
Q
130 Vdc 113 Vdc to 145 Vdc, 1A
When using one or more external power supplies, all power outputs (including
returns) MUST have disconnect devices rated at 3A.