26
8-card Shelf CCC model 751109/15
3.3
Ground Connections
³
To connect the ground of the 8-card Shelf
For an illustration of the shelf power access, refer to Figure 2 on page 28.
C
AUTION
Q
The equipment ground must be connected before any other connection
is made to the shelf.
Q
Connect the Station ground lug to the Station ground bar or ground rod
using a #6 AWG wire - green with yellow stripes. The preferred length of
this wire is 3 meters (10 feet) or less. The ground lug is the
recommended method of grounding the shelf.
Q
If a ground bar or ground rod is not available to connect the ground lug,
it is possible to use the power cord ground wire. Refer to step 3. on
page 29.
N
OTE
Q
All shelves must be permanently connected to earth.
Q
The ground wire must be of gauge AWG #6, color green with a yellow
stripe.
Q
Installations must conform to local electrical code.