background image

 

 
 
 
 
 

FCC Notes: 

This  equipment  generates,  uses,  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and 
used in accordance with the instructions manual, may cause interference to radio communications. 
It has been tested and found to comply with limits for a Class A digital device pursuant to subpart 
J  of  Part  15  of  FCC  Rules,  which  are  designed  to  provide  reasonable  protection  against 
interference  when  operated  in  a  commercial  environment.  Operation  of  this  equipment  in  a 
residential area is likely to cause interference in which case the user at his owns expense will be 
required to take whatever measures to correct the interference. 
 

Warranty Limits: 

Warranty  terminates  automatically  when  any  person  other  than  the  authorized  technicians  opens 
the machine. The user should consult his/her dealer for the problem happened. Warranty voids if 
the user does not follow the instructions in application of this merchandise. The manufacturer is by 
no means responsible for any damage or hazard caused by improper application. 
 

About This Manual: 

Posiflex has made every  effort for the accuracy of the content in this manual. However, Posiflex 
Technology, Inc. will assume no liability for any

 

technical inaccuracies or editorial or other errors 

or  omissions  contained  herein,  nor  for  direct,  indirect,  incidental,  consequential  or  otherwise 
damages,  including  without  limitation  loss  of  data  or  profits,  resulting  from  the  furnishing, 
performance, or use of this material. 

 

This  information  is  provided  “as  is”  and  Posiflex  Technology,  Inc.  expressly  disclaims  any 
warranties,  expressed,  implied  or  statutory,  including  without  limitation  implied  warranties  of 
merchantability or fitness for particular purpose, good title and against infringement. 
The information in this manual contains only essential hardware concerns for general user and is 
subject  to  change  without  notice.  Posiflex  Technology,  Inc.  reserves  the  right  to  alter  product 
designs,  layouts  or  drivers  without  notification.  The  system  integrator  shall  provide  applicative 
notices and arrangement for special options utilizing this product. The user may find the most up 
to date information of the hardware from: http://www.posiflex.com or http://www.posiflex.com.tw 
or http://www.posiflexusa.com 
 
All  data  should  be  backed-up  prior  to  the  installation  of  any  drive  unit  or  storage  peripheral. 
Posiflex will not be responsible for any loss of data resulting from the use, disuse or misuse of this 
or any other Posiflex product. 
 
All  rights  are  strictly  reserved.  No  part  of  this  documentation  may  be  reproduced,  stored  in  a 
retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, 
or otherwise, without prior express written consent from Posiflex Technology, Inc. the publisher of 
this documentation. 
 

©

 Copyright Posiflex Technology, Inc. 2010 

All  brand  and  product  names  and  trademarks  are  the  property  of  their  respective  holders.

XP-3000/3300 Series 

Fan Free Touch Terminal 

User’s Manual

 

Rev.: B0 

P/N: 

15480900030

 

Содержание XP-3000 Series

Страница 1: ...fits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory...

Страница 2: ...the busiest situation XP 3000 3300 Series applies Intel Pine View CPU technology fast speed Ethernet as well as plenty of connects ports of USB Serial VGA and CR ports It also integrated with thermal...

Страница 3: ...Page 2 INTRODUCTION PRODUCT PICTURES Front Views Side Views Rear Bottom Views 1 2 3 4 5 6 7 8 9 10 11 14 15 16 17 9 12 13...

Страница 4: ...Exit 14 Bottom plate compression lock 15 Bottom plate tenon 16 Rubber foot with bottom plate fixing screw 17 Bottom plate PRODUCT FEATURES Standard Features Models Item XP 3012H XP 3015H XP 3312H XP 3...

Страница 5: ...imum Paper roller diameter 80mm Paper thickness Less then 86 m LCD panel tilt angle 14 55 degree Table Summary of features Models Item XP 3012E XP 3015E XP 3312E XP 3315E LCD Display TFT LCD Panel Dig...

Страница 6: ...tems Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SODIMM memory expansion up to 2GB...

Страница 7: ...ple push on the switch in 10 sec may turn off the power Note There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully Brightness Control I...

Страница 8: ...video memory size is default in 128 MB and can be set to be 64 MB VGA Port The VGA port in the XP 3000 3300 system supports either a rear mount 2nd display or a separately connected LCD monitor or tou...

Страница 9: ...mouse at the point when the touch panel is touched If the point touched is dragged across the screen surface it works as the mouse drag and drop feature If the point is touched released and touched wi...

Страница 10: ...e that the push lock button in the lock release lever When the LCD panel needs to be push or pull from the most rear end please press the push lock and the lock release lever at same time then the LCD...

Страница 11: ...in order to reduce the paper loss adjustable function please see following chapter Printer setup The printer will leave the advance paper in 4 8 mm long for each print It is highly suggested to print...

Страница 12: ...ard s movement can be two way of the slot the reading process should be passing through whole slot horizontally A non standard card recorded without complete degaussing prior to recovery may accept on...

Страница 13: ...e at right Next please unfasten these two screws which fasten the UPS bracket and take out the bracket as shown in the lower left picture Please take it out and place it in the battery compartment at...

Страница 14: ...and pull up the terminal carefully than you will see the I O plate I O Plate View A 2x Serial Port RS 232 COM1 2 B 1x Serial Port RJ 45 COM3 C 1x LAN Port D 4x USB Ports E 1x CR Ports F 1x VGA Port D...

Страница 15: ...connector be screwed into place once seated Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector...

Страница 16: ...t customer display kits for XP 3000 3300 series Counter space saving design with 2 20 VFD PD 2606 and 2 20 LCD PD 330 provides the clearest view for customers In addition real base mount graphic STN L...

Страница 17: ...he CR port in XP system This cable has a 6 pole plug at one end and an 8 pole plug at the other The 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear o...

Страница 18: ...on This terminal must NOT be operated in an environment with restricted ventilation There must be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around t...

Страница 19: ...iately A larger external battery may be connected to give an extended operation Please check your dealer about this capability when required WARNING If there are any signs of over charging or leakage...

Страница 20: ...in system jumper setting and printer parameter setting However such support is limited to the application of specific Posiflex peripherals and must be disabled when the Posiflex peripherals are disco...

Отзывы: