OPERATING SYSTEM INSTALLATION 

This  product  is  highly  professionalized  equipment.  The  installation  of  an  OS 
into  a  machine  without  any  preloaded  OS  could  be  a  major  difficulty  for 
average  user  or  obstacle  by  possibly  unintentional  negligence  even  for  PC 
veterans  to  accomplish  such  a  task.  Therefore,  OS  installation  into  a  system 
without  preloaded  OS  is  highly  discouraged.  Posiflex  Technology,  Inc.  shall 
not be responsible for any technical support to questions on this aspect. 
 

USING THE TOUCH TERMINAL 

APPLICATION ENVIRONMENT 

It is 

very

 important that you check the following operational guidelines: 

 

Ventilation 

This  terminal  must 

NOT

  be  operated  in  an  environment  with  restricted 

ventilation. There must be at least 25 mm air clearance around any top or side 
ventilation  holes  with a free flow of air around the  unit at 

ALL

 times for the 

installation. 
 

Operating Environment 

The equipment must not be operated or stored in extremes of both temperature 
and humidity/moisture. (Operating range 0°C to 40°C and up to 80% humidity 
– non condensing, max. wet bulb 26 C) 
 

Power Supply 

The operating voltage range of the power adaptor should cover the local power 
supply for proper operation. The power cable, the power outlet and any power 
fusing arrangements must conform to local safety regulations. 
 
Please 

never do any connection / disconnection

 when system is still powered 

on. 

Please  always  keep  the  external  power  adaptor  in  a  free  air 

circulation. 
 

POWER ON/OFF 

Touch Open Cover 

A gentle tap on the touch open cover at left side 
of  the  main  unit  will  open  the  cover  and  show 
the  power  switch  at  top  area.  It  is  preferable  to 

Содержание KS - 6715

Страница 1: ...ata or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essentia...

Страница 2: ...batteries and always replace only with battery of same type DAILY MAINTENANCE GUIDE For regular cleaning of the KS systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent You ...

Страница 3: ...oam out from the carton please remove the PE foam with extra care and make sure place the terminal and stand on a soft clean flat surface such as table and as show in the picture at the right side Please find the four holes in the top of stand Take the stand and align these four matching holes to the four matching pegs which are in the back on terminal After matching the stand and terminal push th...

Страница 4: ...r Views Side Views PARTS IDENTIFICATION 1 Main Unit 2 Touch panel LCD panel 3 Power indicator 4 Gen 5 base stand 5 Screw holes for optional rear top mount kit such as PD 310 or Base Stand and Bottom View Inside touch open door 7 8 9 10 15 16 17 14 18 19 11 12 13 2 3 1 4 5 6 ...

Страница 5: ... USB ports 11 Base stand 12 Compression lock for base stand cover 13 Cable exit 14 Cable groove 15 Cable exit 16 Cable holder 17 Bottom plate 18 Cable passage in bottom plate 19 Rubber feet with bottom plate fixing screw PRODUCT PICTURES for Gen 6 Base Stand Side Views 1 2 3 Front View Rear View 4 5 Inside touch open door 6 7 8 9 ...

Страница 6: ...crew 14 UPS battery bracket PRODUCT FEATURES Standard Features a CPU VIA Nano 1 6G CPU 1M Cache b Fan free structure with Aluminum die cast main unit casing for harsh environment c Data storage device 2 5 SATA HDD in main unit or optional SSD in main unit or optional SATA HDD in base d An advanced slim base design that supports 2nd LCD display or pole mount customer display on rear base storage ro...

Страница 7: ...6 one SATA port with one 4 pin power connector for optional SATA HDD in base 7 LED indicators for systems operation status 8 one CR port capable of controlling 2 cash drawers max 9 reserved one LPT interface through use of optional special cable in service window 10 one 4 pin DIN type DC 12 V power input connector l Touch control functions left right button double click drag draw m Dual display su...

Страница 8: ...2312 12 second LCD monitor or LM 8035 15 second LCD monitor i Preload OS Win XP Pro POS Ready Win 7 or Linux j Wireless LAN adaptor in USB interface k Split cable for 2 cash drawer control l LPT interface conversion cable m Wall mount kit WB 6000VB INSTALLATION GUIDES CAUTION Before any installation or cable connection to the set please always make certain that the system is turned off and the ext...

Страница 9: ...ble then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port or the CR port Please also note that the fixing screws have to be loosened free prior to disconnect...

Страница 10: ...cable passage to main unit in desktop mount application Pull the compress lock to open the back cover of base stand Hold them together with a cable tie Pass all cables through the cable exit to external connections OPENING STAND ASSEMBLY for Gen 5 Base Take the adjustable stand assembly and turn it up side down to show the bottom of the base Remove the bottom plate fixing screws in rubber feet to ...

Страница 11: ... main unit there is a service window Remove the service window lock screw where the DDR3 SODIMM 2nd HDD power and signal connector several jumpers and a reserved LPT port are sited Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops The option LPT conversi...

Страница 12: ...e mount kit removed in the future BASE MOUNT UPGRADE KIT Please follow the instructions on the manual that comes along with the customer display PD 306 2602 76X2 LM 8015 LM 8025 LM TM 8045 LM 8055 if installed REAR TOP MOUNT UPGRADE KIT 1 For Customer Pole Display Please apply carefully the 2 small fixation shoulder screws that come along with PD 310 or PD 2604 to the back of KS 6715 at the screw ...

Страница 13: ...im to join bracket which just fixed on the main unit and fasten these 3 pcs short screws which circled in the right picture Next please connect the VGA Cable to the LM VGA port and route the VGA cable through the cable exit of the base stand to the system VGA ports Note When KS 6715 series equipping with LM 80X5 series 15 second LCD monitor the power adaptor must be upgrade to 80W CONNECTING CASH ...

Страница 14: ...assembly Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector please always hold the connector head itself instead of pulling on the cable wire Failure to do this could damage the cable and jack that is considered as an artificial destruction and is not covered by the warranty DESKTOP MOUNTING Ma...

Страница 15: ... on HDD Posiflex provides recovery DVD delivered with the touch terminal for the preloaded operating system The System Integrator shall take care of software restoration after OS recovered A Posiflex supplied USB interface COMBO drive will be required for such action Other brand CDROM drive may require its own driver different from what supported in the recovery DVD Please use the recovery DVD in ...

Страница 16: ...ust be at least 25 mm air clearance around any top or side ventilation holes with a free flow of air around the unit at ALL times for the installation Operating Environment The equipment must not be operated or stored in extremes of both temperature and humidity moisture Operating range 0 C to 40 C and up to 80 humidity non condensing max wet bulb 26 C Power Supply The operating voltage range of t...

Страница 17: ...s present This switch turns the system off when pushed again during power on status However if the system hangs due to any reason such as software resource conflict a simple push on the switch may fail to turn off the power In this case please utilize the forced power off feature by pressing the switch and holding for within 10 seconds In case the turmoil is so vigorous that some hardware register...

Страница 18: ...up and an operating caller system connected through LAN to the system is required It also requires a qualified networking technician to check the LAN chip ID of the system for the caller system to wake up When the KS system is turned off after a successful boot up the preset automatic power on functions will keep monitoring for the preset conditions and turn on the system when the preset condition...

Страница 19: ...6715 system there are 4 serial ports in form of DB 9 pin male connectors supply a 5 V through BIOS setup or 12V DC setup up by jumper setting However do not connect any other device to this port before the power in this port is disabled PARALLEL PORT In KS 6715 system the parallel port can be available only through use of the optional conversion cable It should be connected to the special connecto...

Страница 20: ...lick on the right button of the mouse at that point Touch Manager Touch Terminal Manager for each type of touchscreen is available for user to set up touchscreen functions If your system is preloaded with the OS of your choice the chances are the Manager is already installed on your system Nevertheless you can also download the Manager from our website 1 Visit us at http www posiflex com and click...

Отзывы: