EMC TEST REPORT
Report No. : EC041208
SPORTON International Inc.
Page Number
: 49 of 63
TEL : 886-2-2696-2468
Issued Date
: Apr. 29, 2010
FAX : 886-2-2696-2255
12. Surge Immunity Test
z
FINAL TEST RESULT
:
PASS
z
Pass Performance Criteria
: A
z
Required Performance Criteria : B
z
Basic Standard
: IEC 61000-4-5:1995/A1:2000
z
Product Standard
: EN 55024:1998/A1:2001/A2:2003
z
Surge Wave Form (Tr/Th)
: 1, 2/50
(
8/20
)μ
s
z
Level
: on Input power ports -- 3
: on signal port and telecommunication ports – N/A
z
Test Voltage
: on Input power ports --
±
1.0 /
±
2.0 KV
: on signal port and telecommunication ports – N/A
z
Temperature :
25
℃
z
Relative Humidity
:
49 %
z
Atmospheric Pressure
:
103 kPa
z
Test Date
:
Apr. 26, 2010
z
Test Mode
:
Mode 1 ~ Mode 2
z
Observation :
Normal.
z
Remark
: The test on signal/telecommunication ports is not required due to
the ports does not connect directly to outdoor cables.
12.1. Test Record
Phase Angle
Voltage ( kV ) Test Location
Polarity
0
°
90
°
180
°
270
°
Test
Result
+
A A A A
PASS
1 kV
L - N
-
A A A A
PASS
+
A A A A
PASS
L - PE
-
A A A A
PASS
+
A A A A
PASS
2 kV
N - PE
-
A A A A
PASS
Remark : PE = Earth reference