![POSIFLEX HT-3200 SERIES Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/posiflex/ht-3200-series/ht-3200-series_manual_1582413016.webp)
EMC TEST REPORT
Report No. : EC041208
SPORTON International Inc.
Page Number
: 12 of 63
TEL : 886-2-2696-2468
Issued Date
: Apr. 29, 2010
FAX : 886-2-2696-2255
4. General Information of Test
4.1. Test Facility
<EMI>
Test Site Location
: No. 30-2, Lin 6, Diing-Fwu Tsuen, Lin-Kou-Hsiang,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2601-1640
FAX : 886-2-2601-1695
Test Site No.
: CO01-LK, OS02-LK
<EMS>
Test Site Location
: 3F, No.587, Tanmeu St., Neihu District,Taipei, Taiwan, R.O.C.
TEL : 886-2-2794-8886
4.2. Test Voltage
230V / 50Hz
4.3. Standard for Methods of Measurement
EMI Test (conduction and radiation) : European Standard EN 55022 Class A
Harmonics Test
: European Standard EN 61000-3-2.
Voltage Fluctuations Test
: European Standard EN 61000-3-3.
EMS Test
: European Standard EN 55024.
(ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, SURGE: IEC 61000-4-5,
CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, DIPS: IEC 61000-4-11)
4.4. Test in Compliance with
EMI Test (conduction and radiation) : European Standard EN 55022 Class A
Harmonics Test
: European Standard EN 61000-3-2.
Voltage Fluctuations Test
: European Standard EN 61000-3-3.
EMS Test
: European Standard EN 55024.
(ESD: IEC 61000-4-2, RS: IEC 61000-4-3, EFT: IEC 61000-4-4, SURGE: IEC 61000-4-5,
CS: IEC 61000-4-6, Power Frequency Magnetic Field: IEC 61000-4-8, DIPS: IEC 61000-4-11)
4.5. Frequency Range Investigated
a. Conducted emission test: from 150 kHz to 30 MHz
b. Radiated emission test: from 30 MHz to 1,000 MHz
c. Radio frequency electromagnetic field immunity test: 80-1000 MHz
4.6. Test Distance
a. The test distance of radiated emission test from antenna to EUT is 10 m.
b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 m.