![POSIFLEX HT-3200 SERIES Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/posiflex/ht-3200-series/ht-3200-series_manual_1582413057.webp)
EMC TEST REPORT
Report No. : EC041208
SPORTON International Inc.
Page Number
: 53 of 63
TEL : 886-2-2696-2468
Issued Date
: Apr. 29, 2010
FAX : 886-2-2696-2255
13. Conducted Disturbances Induced by Radio-Frequency Field Immunity
Test ( CS )
z
FINAL TEST RESULT
:
PASS
z
Pass Performance Criteria
: A
z
Required Performance Criteria : A
z
Basic Standard
: IEC 61000-4-6:1996/A1:2000
z
Product Standard
: EN 55024:1998/A1:2001/A2:2003
z
Level :
2
z
Test Voltage
: 3 V (unmodulated, r.m.s) 80% AM (1 kHz)
z
Frequency Range
: 0.15 MHz to 80 MHz
z
Additional Selection Frequency : 0.2, 1, 7.1, 13.56, 21, 27.12, 40.68MHz
z
Dwell Time
: 2.9 seconds
z
Frequency Step Size
: 1 %
z
Coupling mode
: CDN-M16 SW M3 for Input power ports,
Clamp for signal port and telecommunication ports
z
Temperature :
25
℃
z
Relative Humidity
:
49 %
z
Atmospheric Pressure
:
103 kPa
z
Test Date
:
Apr. 26, 2010
z
Test Mode
:
Mode 1 ~ Mode 2
z
Observation :
Normal.
13.1. Test Level
Level
Voltage Level ( EMF )
1
1 V rms
2
3 V rms
3
10 V rms
x Specified
NOTE - x is an open class.
This level can be specified in the product specification.