[on/off] SEND REPORT IF ADC1 GO DOWN [down voltage] V for [debounce time] SEC
[on/off] SEND REPORT IF ADC1 ENTER/EXIT [min voltage] V TO [max voltage] V for [debounce time] SEC
Note: AD1 input voltage range is 0~3.3v, it must connect a resistance to share the voltage if the detected voltage higher
than 3.3v,.
(4) Speeding report
The UNIT will automatically check the current speed information; it will send a report to the server when it is over the
defined maximum speed.
(5) Low battery warning report (to alert user when the backup battery level is low)
Parameters: On/Off, and warning battery level for report. For example, 30 to represent 30% lower level report.
The system will ignore the parameter with a value ‘0’ to prevent continuous non-stop reporting.
(7) Course change report
Parameters: On/Off, and course change in degree.
(8) Keep alive procedure
Parameters: On/Off, and interval / retry times. In order to keep connection in GPRS network, the unit can be set to send
short keep alive report to the server in order to prevent the disconnection from the mobile service provider.
Send reports after a successful keep alive ACK. Parameters: On/Off .
If you select this function, all the reports will only be sent out after a successful keep alive ACK. (So if your keep alive
time is shorter then select this function will be OK.) This function is very useful while using UDP to prevent report lost.
Send a keep alive packet right before a due reports if no data stream within certain time: Parameters: On/Off, and idle
time.
Some GSM provider might cut connection, if there is no data within certain time. It might result report lost in this “fake
connection” duration. For example, you can set parameters in this region, ex 20 mins. (it means if the unit did not send
any data in this 20 mins (including keep alive or normal reports) ), then it will send a keep alive packet to check if the
GPRS connection is valid or not. If not, it will actively reconnect to GPRS network.
(9) Fixed time report
Parameters: On/Off, and time. The unit will send out a report every fixed duration.
(10) Fixed distance report
Parameters: On/Off, and distance. (min. distance is 0.1 km, max. distance is 100 km).
(11) GPRS dial-up procedure
1) GPRS always one-line
Parameters: Reconnect interval
While using this mode, when the unit can not searched GPRS signal, system will reconnect GPRS interval a preset value.
(e.g.: 1minute)