background image

 

13 

 

FLOWMETER ACCESSORIES 

 

Three or Two Liter Reservoir Bag 

Install the reservoir bag by sliding the opening over the outside of the bag tee downspout.  The bag 
moves in and out with each inhalation and exhalation and becomes a visual barometer for monitoring the 
patient’s respiration rate. Refer to FM-809 for User Instructions, Assembly, Installation and Cleaning.

 

 

Gas Scavenger Breathing Circuit 

 

Gas scavenger system is used to remove exhaled gases during a dental analgesia conscious sedation 
procedure in a dental operatory. The breathing circuit consists of a 22mm 90° elbow connector, fresh gas 
/ coaxial tubing, a corrugated hose and hood assembly.  Attach the nasal inhaler to the coaxial tubing 
assembly using the diameter-indexed connectors. Attach one end of the fresh gas corrugated tubing to 
the coaxial tubing assembly at the fresh gas “Y” connector and the other end to the 22mm right angle 
adapter. Press fit the 22mm right angle adapter onto the bag tee.  Attach a 2L or 3L reservoir bag to the 
bottom / downspout of the bag tee. Attach the vacuum hoses to the vacuum control source (AVS or In-
line Vacuum Control Block).  Refer to FM-809 for User Instructions, Assembly, Installation and Cleaning. 

 

 

Figure 9.  5061 Connector Installation 

 

Gas Scavenger Breathing Circuit (with AVS) 

 

The AVS is used to control the vacuum flow in the gas scavenger breathing circuit and assure that the 
scavenging system is activated as soon as N

2

O / O

2

 is turned ON.  Adjust the vacuum flow using the 

control knob.  Vacuum flow is most effective when the ball float is set within the green bar area.   
Installation of AVS to Flowmeter:  Screw AVS 5000 knurled seal nut down tight onto flowmeter making 
sure the rubber washer is inside the seal nut.  When tight, the AVS should not rotate.  Then, screw the 
bag tee seal nut onto the AVS.  Bag tee should not rotate.  Connecting AVS to Vacuum Hoses:  Attach 
one end of the vacuum hose to the vacuum hose “Y” connector and the other end to the MASK port of the 
AVS. Attach a second vacuum hose to the VAC port of the AVS and the other end to the vacuum source.  
Refer to FM-809 for User Instructions, Assembly, Installation and Cleaning. 

 

 

 

5061 Connector Installation 

Содержание DIGITAL MDM

Страница 1: ...ration is The design manufacture distribution and servicing of Nitrous Oxide Oxygen Sedation Flowmeters Gas Scavenging Systems Gas Distribution Systems and Office Communication Systems for use by a ph...

Страница 2: ...own protection as well as that of the Doctor and the patients use 3 8 O D tubing for all Nitrous Oxide lines and O D tubing for all Oxygen lines To assure safe operation and conformation to local fire...

Страница 3: ...A known Protective Earth ground connection must be made via one of the following methods 1 The third wire on the power cord when plugged into an appropriate outlet that is properly installed and grou...

Страница 4: ...ropriate regulatory authority in your country state or province Training is recommended to provide a practical hands on capability and an understanding of the behavioral aspects of Nitrous Oxide Sedat...

Страница 5: ...or pipeline gas systems and delivers the electronically controlled mixture to the bag tee outlet Built In Safety A series of alarms see Safety Alarm System page 6 alert the user to any problem conditi...

Страница 6: ...n restored either by disconnecting reconnecting the power cord or by local power failure the unit will display OFF The operator must press the ON OFF key to restart the unit The unit will then display...

Страница 7: ...leasing the key returns the unit to the flow rate and mixture ratio which were in effect prior to the flush Alarm Test Silence Key The alarm test silence key serves two functions When pressed all the...

Страница 8: ...8 PORTER DIGITAL MDM SYSTEM ILLUSTRATION...

Страница 9: ...alve 9A B 2461 001 N2O Check Valve 10 8005 O2 Hose Diss Diss 5 Ft 10A 8505 N2O Hose Diss Diss 5 Ft 10B 80012 O2 Hose Diss Diss 12 Ft 10C 85012 N2O Hose Diss Diss 12 Ft 11 PA 450 1 002 O2 Hose 12 Ft 11...

Страница 10: ...ews again Bracket B 5485 Figure 3 Control Unit mount directly to wall 3 Use bracket shown in Figure 4 for under cabinet mounting Turn same bracket upside down not shown for table top mount Kit B 5555...

Страница 11: ...NLET fitting on the back of the mixer head see Figure 6 Hand tighten and then finish tightening with a 7 8 inch open end wrench approximately 1 8 turn Do not over tighten 2 Connect the DISS female hex...

Страница 12: ...12 Figure 6 Connection to the back of unit Figure 7 Installation of Power Cord Figure 8 Connections Schematic some components may not be part of your installation Power Cord N2O DISS O2 DISS...

Страница 13: ...servoir bag to the bottom downspout of the bag tee Attach the vacuum hoses to the vacuum control source AVS or In line Vacuum Control Block Refer to FM 809 for User Instructions Assembly Installation...

Страница 14: ...g the cut ends of the tubing to both ends of the vacuum control block Adjust the vacuum flow using the control knob Vacuum flow is most effective when the ball float is set within the green bar area R...

Страница 15: ...ve See Fig 10 below is not functioning properly and should be replaced Figure 10 Emergency Air Valve Check Monthly Place the On Standby switch in the STANDBY Off position Disconnect the corrugated rub...

Страница 16: ...1 to 4 years requires caution and specific protocols developed by the medical professional upper age limit at determination of medical professional Weight limitations at the determination of medical p...

Страница 17: ...n Failure Test Set the LPM FLOW display to 9 9 LPM Set the OXYGEN display to 50 Turn off the oxygen gas supply to the unit When the gas runs out check for each of the following the OXYGEN FAILURE alar...

Страница 18: ...Handbook of Nitrous Oxide and Oxygen Sedation written by Clark and Brunswick and published by Mosby www mosby com This text is a concise and contemporary guide for nitrous oxide oxygen administration...

Страница 19: ...nimum Nitrous Oxide Concentration 00 Maximum Nitrous Oxide Concentration 70 Minimum Oxygen Concentration 30 Maximum Oxygen Concentration 100 Flow Range 100 Oxygen 1 0 to 9 9 LPM Flow Range Any Mixture...

Отзывы: