background image

6

SPORTSONIC

£

 II

INSTALLATION AND OPERATING INSTRUCTIONS

PARTS LIST 

  

 

12002-200 

12002-250 

Item No. 

Part No. 

Quantity 

Quantity  Description

 

XELC 12002 200 

Sportsonic

£

II Receiver 

 

2 ELEC 

00064 

000 1 

1  3-Prong 

Twist-Lock 

Receptacle 

 

ELEC 00126 0G0 

1/2" deep Cover Plate 

 

ELEC 00221 002 

Cable Tie 14" Lg. - Black 

 5 

12002-100 

 Sportsonic

£

 Transmitter – 99 Positions 

 

ELEC 00086 000 

 

Key Switch Assembly 

 

Quantity of Sportsonic

£

II Transmitters to be specified 

 One 

Sportsonic

£

II Receiver required per device to be controlled. 

1.  Establish backstop or divider curtain operating code numbers (1 thru 99).  Use numbers on floor plan drawing if available – Main 

court #1 and 2, Cross Courts #3, 4, 5, 6, etc.  Suggest marking backstops with operating numbers to avoid confusion. 

2.  At the cord connector end of Sportsonic

£

II receiver enclosure, rotate small cover up, to expose DIP switch window.  Locate 

receiver DIP switch module inside enclosure window (small black plastic module with white slide tabs numbered 1 thru 7).  Set 
the receiving code module on each receiver per the following chart.  As each box is set and DIP switch cover closed, write the 
operating identification number (1 thru 99) on the outside of the box. 

ON

1

5

3

2

4

7

6

OFF

DIP SWITCH SETTING EXAMPLES

ADDRESS No. 2

ADDRESS No. 1

ADDRESS No. 3

DIP SWITCH ADDRESS CHART

13

21

23

24

25

22

17

19

20

18

15

16

14

9

11

12

10

8

7

6

5

4

3

2

1

2

1

3

7

5

4

6

38

46

48

50

49

47

42

44

45

43

40

41

39

34

36

37

35

32

33

30

31

1

28

29

26

27

6

4 5

3

2

7

63

71

75

72

74

73

67

68

70

69

64

65

66

54

59

60

62

61

55

57

58

56

2

1

51

53

52

7

4

3

5 6

88

99

98

97

96

95

94

93

92

91

90

89

87

86

85

84

83

82

81

80

79

78

77

76

5

3 4

1 2

6 7

ADDRES

S

DIP SWITCH

DIP SWITCH

ADDRES

S

ADDRES

S

DIP SWITCH

ADDRES

S

DIP SWITCH

OFF

ON

1 2 3 4 5 6 7

OFF

ON

ON

1

5

3

2

4

7

6

OFF

Содержание 12002 Sportsonic II

Страница 1: ...OTE CONTROL SYSTEM FOR BASKETBALL BACKSTOPS GYMNASIUM DIVIDERS ETC No 12002 Sportsonic II INST 00358 042 2015 PORTER ATHLETIC INC ALL RIGHTS RESERVED 11 6 2015 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND TO ORDER REPLACEMENT PARTS ...

Страница 2: ...2 ...

Страница 3: ...y Enclosure shall be furnished with a 4 pole twist lock grounded type NEMA L14 20 receptacle to accept the power control cable from the electric winch Receiver shall allow for dual control of equipment Sportsonic II or key switch Each radio controlled receiver shall include an external 3 screw terminal strip for optional low voltage key switch type control The terminal strip shall allow for connec...

Страница 4: ...4 ...

Страница 5: ...rs for power supply Enclosure shall be furnished with a 4 pole twist lock grounded type NEMA L14 20 receptacle to accept the power control cable from the electric winch Receiver shall allow for dual control of equipment Sportsonic II or key switch Each radio controlled receiver shall include an external 3 screw terminal strip for optional low voltage key switch type control The terminal strip shal...

Страница 6: ...portsonic II receiver enclosure rotate small cover up to expose DIP switch window Locate receiver DIP switch module inside enclosure window small black plastic module with white slide tabs numbered 1 thru 7 Set the receiving code module on each receiver per the following chart As each box is set and DIP switch cover closed write the operating identification number 1 thru 99 on the outside of the b...

Страница 7: ...m the V belts and pulleys when operating unit A Set selector display 1 thru 99 to position 1 by pressing the next button The numeric LED will illuminate displaying the address 01 see illustration above B Press RAISE button backstop or gym divider curtain marked No 1 should begin up cycle C Set rotary counting limit switches per winch installation instructions D Repeat steps A thru C for all units ...

Страница 8: ... connection of low voltage dry circuit type 5 volt maximum key switch wires up down and common Refer to the diagram below for wiring details Note Do not connect high voltage key switch wires to the receiver terminals Introduction of powered key switch wires at the terminal strip will permanently damage the receiver CAUTION WIRING AT WALL MOUNTED KEY SWITCH WIRING AT RECEIVER POWER SOURCE JUNCTION ...

Страница 9: ...se 12002 100 TRANSMITTER Stand within 50 feet of unit number 1 To raise the unit press the RAISE button and hold during the up cycle until the limit switch stops the unit To lower the unit press the LOWER button and hold during the down cycle until the limit switch stops the unit To stop the operation of the unit release the button To reverse the operation of the unit allow the unit to come to a c...

Страница 10: ...y proof of purchase If service is required under this warranty 1 Call or write to Porter Athletic Inc for a Return Merchandise Authorization number to be affixed to returned packaging This RMA number will also be your reference number 2 Return defective unit postage or freight prepaid to Porter Athletic Inc 601 Mercury Drive Champagin Illinois 61822 3 Enclose dated proof of purchase 4 Enclose chec...

Страница 11: ...11 THE OWNER OF THIS EQUIPMENT MUST SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND TO ORDER REPLACEMENT PARTS ...

Страница 12: ...m 888 277 7778 THIS WARNING IS GIVEN IN COMPLIANCE WITH CALIFORNIA S PROPOSITION 65 WARNING This product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING Cancer and Reproductive Harm For more information go to www p65warnings ca gov F ...

Отзывы: