3
SPECIFICATIONS
PORTER No. 12002-200 SPORTSONIC
£
II SPORTS COMPLEX CONTROL SYSTEM
(FOR OPERATION OF No. 00706-000 or 00707-000 ELECTRIC WINCHES OR No.
665, 670, 675 or 2080 DIVIDER CURTAIN OPERATORS)
Winch shall be controlled by a radio control system (Sportsonic
£
II) to eliminate complicated control wiring, wall boxes and
individual key switches as on conventional remote control key switch systems. Sportsonic
£
II portable hand-held
transmitter (5-1/2" x 3-3/8" x 1") shall be specified. The No. 12002-100 transmitter will operate up to ninety-nine individual
winches. Numeric LED clearly displays selected channel. Power supply for transmitter shall be a standard 9-volt battery.
Transmitter shall operate on a digitally encoded carrier frequency of 315 MHz.
Each electric winch shall be equipped with a commercial type 115 VAC receiver with a coding switch for individual
operation by the portable transmitter. Receiver shall be factory wired and installed in a standard non-metallic enclosure
(6" x 4" x 2-3/8") with a 6’-0" long SJ cord with a NEMA L5-15 molded twist-lock grounded plug attached. Matching flange
type receptacle shall be mounted in a standard 4" square cover plate (box by others) for power supply. Enclosure shall be
furnished with a 4-pole twist-lock grounded type NEMA L14-20 receptacle to accept the power/control cable from the
electric winch.
Receiver shall allow for dual control of equipment (Sportsonic
£
II or key switch). Each radio-controlled receiver shall
include an external 3-screw terminal strip for optional low voltage, key switch type control. The terminal strip shall allow
for connection of low voltage, dry circuit type (5 volt maximum) key switch wires (up, down and common). Circuit board
programmed EEPROM shall provide logic for an interlocking feature to eliminate conflict between radio and key switch
control input. Key switch option shall be specified when a secondary or back-up method of winch operation is desired.
Radio control systems without optional low voltage, key switch type control shall not be considered equal.
All units to be factory tested for a 100' (nominal) operating range. Coding switch shall be configured in field for
independent operation.
Wiring of all electrical components shall be in accordance with local codes, and in accordance with manufacturer's
instructions.
All conduit, wiring, junction boxes and components not specified herein shall be furnished and installed by the electrical
contractor.
ISSUED NOVEMBER 6, 2015, SUBJECT TO CURRENT MANUFACTURING PROCEDURES AND CHANGES
COPYRIGHT 2015 – PORTER ATHLETIC EQUIPMENT COMPANY – ALL RIGHTS RESERVED
B-2002