17
Installation Instructions
US
FC
ESM
Cable accesses and electrical supply
The Wall Charger Connect is designed for installation
with cable conduits. Access to the Wall Charger
Connect is possible from above or below.
Fig. 11: Upper and lower cable access (rear view of the Wall
Charger Connect, cable conduits are marked in blue)
The following criteria must be observed when
selecting and installing cable accesses:
– The Wall Charger Connect can accommodate
cable conduits between ¾ inch and 1 ¼ inch.
– The cable conduits used must be metal, and
flame-retardant.
– Always used sealed cable conduits so that a
degree of protection of 3R can be ensured.
– Always use a UL-certified cable conduit system.
– Metallic cable conduits are not grounded through
the Wall Charger Connect. Conduit grounding
must be ensured by a qualified electrician.
– The Wall Charger Connect is designed for
connection cables from AWG 0 to AWG 4.
– The Wall Charger Connect is designed exclusively
for the connection of copper wires.
When using an AWG 4 supply cable, it must have
a temperature rating of 90 degrees.
When using a supply cable of AWG 3 or larger,
this cable must have a temperature rating of
75 degrees.
– Use a fuse that guarantees reliable operation of
the Wall Charger Connect.
– If your power supply does not permit 80 A, the
electric current of the Wall Charger Connect can
be limited during installation.
Installation materials required
The following material is required for the installation:
– Cables and cable conduits including tight cable
conduit fittings
– Duct seal
– Fastening materials for wall installation (flat head
screw 8 x 200; wall plugs to suit the wall)
Tools required
The following tools are required:
– Torx screwdriver TX 25
– Philips screwdriver
– Holesaw for the cable conduit
– Small screwdriver
– Pliers to remove insulation from the wires
– Small hacksaw
– Knife
– Torque wrench
Installing
Unpacking
e
Remove the contents from the package and
check that all parts are present and undamaged.
Installing the cable conduit access
1.
Lay the supply cable to the place of installation of
the Wall Charger Connect.
2.
Install a suitable fuse and use a fire-retardant
cable conduit system.
DANGER
Electric shock, fire
Incorrectly installed connections can cause electric
shock or fire when the high-voltage battery is
charged using the vehicle charge port.
e
Switch off the supply voltage and make sure that
the voltage is off before installation works are
performed.
e
Observe the locally applicable electrical
installation regulations, fire protection measures,
accident prevention regulations and escape
routes.
Information
The outer shell is only a cosmetic cover. Do not screw
any cable conduit fittings to it. The Wall Charger
Connect must be opened internally for installation
works.
Information
Ensure when drilling that no shavings fall into the
interior of the Wall Charger Connect.
e
If shavings do fall into the interior, remove these
before continuing with the installation.