ENGLISH
FLOORLESS COLDROOM (SRC-Room)
When installing a fl oorless coldroom, ensure that the corners do
have an angle of 90°.
FLOORLESS ROOMS ARE SUPPLIED
WITH 90° ANGLE TO ENSURE CORNERS ARE STRAIGHT.
IF UNSURE PLACE ROOF PANEL/PANELS ON FLOOR (IF A
TWO OR THREE PIECE ROOF IS SUPPLIED ENSURE CAM
LOCKS ARE TIGHTENED) THEN MARK AROUND. PLACE
PLINTH ON FLOOR FOLLOWING MARKS FROM ROOF
PANEL/PANELS, SECURE USING FIXINGS PROVIDED.
FOR MORE DETAILED INSTRUCTIONS, PLEASE SEE THE
TABLES OF BASE MOUNTING PROFILES IN THE END OF
THIS MANUAL.
• Place the two longest lengths of plinth on the fl oor. Ensure the
fl oor is level, some packing can be placed under plinth
sections to maintain level. Using 90
o
angle provided ensure
corners are true.
• Layout rest of plinth sections provided, once again ensuring
corners are at a true 90° angles (pic.4). Check the outer
dimensions will suit room being assembled. Drill holes
through plinth in to fl oor and secure with fi xings provided.
NOTE: Leave 4 fi xings for doorframe supports.
• Fix corner angle plates (pic. 5) with screws provided.
• After erecting cold room following usual guidelines given
earlier, the stainless steel covers can be attached with fi xings
provided to cover the ends of plinth at door entrance, the
shorter
fl ange should be to the front (pic. 7). Fill any gaps with
clear silicon mastic. The stainless steel ‘L’ brackets can be
fi xed inside the door to the fl oor and frame to give strenght to
the frame frame when trolleys are being used.
The massive selection of rooms offered, dictates a large
number of different panel widths and corner sizes are supplied.
It is essential that you carefully study the plan drawing detailling
panel layout. This must be followed at all times.
• Begin the installation by positioning the cooling unit to either
front left or right hand of the rooms and mount on plinth or
fl oor. (Note care should be taken to ensure the unit is
balanced and not fall over). Then place wall panel and
build according to plan.
When installing wall panels, pay attention to the following:
• Do not fully tighten cam-locks wall/fl oor, wall/wall, until the roof
panel has been fi tted. This allows some movement to align all
panels.
• begin the installation with the wall and corner panels adjacen
to any existing brick walls, then fi t the remaining panel
sections.If possible do not install the machinery or door
section
last
• before fi nal tightening of wall panel cam-locks and fi tting roof,
ensure that the tops are level.
• when installing door panel, secure the handle to the door by
screwing the emergency release opener in to the lock
mechanism through the door panel from the inside. Note take
care not to cross-thread inner release in the handle.
Secure the emergency opener’s cover plate with screw
provided.
ALWAYS CHECK SATISFACTORY FUNCTION OF
EMERGENCY INNER RELEASE
• Before fi tting roof panels ensure power cable for
machinery unit is to the outside.
• One piece roof panels can then be lifted into place and locks
tightened. If the roof is in sections, lift all roof panels in
place from rear forward or side by side and tighten roof
sections together, the roof to wall panel lock can then also be
tightened. All locks should now be fully tightened and the
white seal caps can now be fi tted to all holes.
Pic. 4. The assembly of the plinths
Pic 5. Corner angle plates
Pic. 6. L-brakets
Pic. 7. The assembly of the wall elements
Pic 6. The assembly of the corner and roof elements
Pic. 7. The Assembly of the door and the emergency door release
Содержание C 1240
Страница 29: ......
Страница 43: ......
Страница 57: ......
Страница 71: ......
Страница 85: ......
Страница 99: ......
Страница 113: ......
Страница 127: ......
Страница 128: ...10156 G H F E B A C D 10152 10154 10155 Wronic 4 2x13 10152 10152 10152 22 5 ...
Страница 129: ...10156 22 5 G H F E B A C D 10152 10154 10155 Wronic 4 2x13 10152 10152 10152 ...
Страница 130: ......
Страница 131: ......