ENGLISH
9
COMBINED ELECTRONIC CONTROL BOARD AND
TEMPERATURE DISPLAY
The equipment is fi tted with a combined digital temperature
display with many built-in features which include; Data
connections for HACCP monitoring of equipment temperatures
and alarms. Volt free relay either normally open or closed
for connection to building maintenance alarm system or
supervising system. XWEB (optional accessory) will allow
HACCP compliance by logging temperature data, alarm history
and will also allow remote control and advise on maintenance of
the equipment.
During normal operation the display will indicate the cabinet
internal air temperature or when ‘dEF is displayed when the
cabinet is taking it’s automatic defrost period.
Keys
The keylock prevents unintended use of the keys.
The lock is switched on by holding the keys down
att the same time for 3 seconds.The display
momentarily shows letters “PoF”. With keylock
on you can still check the lowest and highest
temperature registered. The light switch function
can still be used when keypad is locked (only on
cabinets fi tted with lights). To unlock the keyboard
keep the keys pressed together for more than
3s. The “Pon” message will be displayed and the
keyboard is unlocked.
To lock and unlock the keyboard
Function of key lamp lights
The key starts drying function to reduce the eventual
humidity on the inner surfaces.
The key for browsing of the temperature data of the
sensors in use.
The key shows the highest thermostat value registered.
In the programming mode you navigate inside the
program or it is used to raise the selected value.
The key shows the lowest thermostat value registered.
In the programming mode you navigate inside the
program or it is used to lower the selected value.
The manual defrosting starts when you push the key for
3 seconds.
The key for checking and changing the settings. In
programming mode the key is used to select the value
and to check the programming function. The registered
value of the highest and lowest temperature can be
deleted by pushing the key for 3 seconds when the value
is displayed.
Light switch (Note! Used only in cabinets with lights)
Power switch
+
Function of the display lights
KEYS
MODE
FUNCTION
Yellow light on
Drying function on
Green light on
Manual defrosting is on
Green light fl ashing
Set temperature is displayed and
can be changed
Green light on
Light inside the cabinet is on
Red light on
The equipment is on standby
mode, ON/OFF
LIGHT
MODE
FUNCTION
On
Compressor is running
Flashing
Time delay to protect compressor after
start-up
On
The fan of the evaporator is on
On
Defrosting is on
Flashing
Time delay after defrost
On
ALARM
On
The fan of the condenser is on
Содержание C 1240
Страница 29: ......
Страница 43: ......
Страница 57: ......
Страница 71: ......
Страница 85: ......
Страница 99: ......
Страница 113: ......
Страница 127: ......
Страница 128: ...10156 G H F E B A C D 10152 10154 10155 Wronic 4 2x13 10152 10152 10152 22 5 ...
Страница 129: ...10156 22 5 G H F E B A C D 10152 10154 10155 Wronic 4 2x13 10152 10152 10152 ...
Страница 130: ......
Страница 131: ......