background image

 

 

 

The device supports secure communication when included with enhanced security option and when communicating 
to a device also supporting enhanced security option. Otherwise the device will automatically turn into normal 
communication to maintain backward compatibility. 

Installation Guidelines 

The device comes ready to use with a battery already installed.  

For battery change the device needs to be opened by removing the three little screws 
on the backside of the device. Use a screwdriver or any other usable device to gently 
push out the battery as shown on the picture. During reassembly watch the position of 
the white rubber and make sure the silver buttons fi t exactly into the nipples of the 
rubber. 

 

The device can be operated in two different modes. These modes are activated with the first configuration action after 
factory default: 

1. 

Pushing 

Button 1 for one sec.

 (red/green blink) adds the KFOB to an existing network as 

secondary 

controller

.  

o

 

The four buttons will send 

activate 4 different scenes

 (Central Scene Command) in the central 

gateway (For this a Z-Wave control center is required. In an existing Z-Wave network the KFOB 

is able to control up to 4 different scenes with its four buttons.) 

2. 

Pushing 

Button 3 for one sec.

 (green blink) turns the KFOB into inclusion status and a Z-Wave actuator 

can be added to the wireless network. Consult the manual of the new device how to start the inclusion 

process (e.g. pushing local inclusion button three times). 

o

 

The KFOB can even control devices without a central controller and will become 

primary 

controller

 of an own Z-Wave network. The connected new device (actuator) can be controlled 

using the two buttons left (Button 1 = up/on/open, Button 3 = down/off/closed). 

When the KFOB is primary controller the very first device included will be automatically put into button group A (left 
buttons 1 and 3) and the command set will change according to the rules just mentioned. All other devices need to be 
put in button groups manually.  

Management Mode

 

After the first action you can further manage (add/remove more devices when primary; wakeup; reset to default) and 
configure the KFOB using the management mode. To activate this management mode push all four buttons for one 

second simultaneously (green blinks slowly). The buttons will have different functions: 

 

When in Secondary Controller Mode: 

 

Push Button 1: Start Learn Mode. This allows to be removed or re-added from/to a network   

 

Push Button 2: Manually wakeup the device and issue a ‘Node Information Frame’ 

 

Push Button 3 followed by Button 4 for 5 Seconds: Reset to Factory Defaults  

When in Primary Controller Mode: 

 

Push Button 2: Manually wakeup the device and issue a ‘Node Information Frame’ 

 

Push Button 3: Activate Primary controller mode. After this you must select the action as primary controller with 
another short click on one of the buttons: 

o

 

Button 1: Start inclusion of a Z-Wave device   

o

 

Button 2: Start forced-unsecure inclusion   

Add as  
secondary 
controller 

Add new 
device to 
controller 
(primary 
controller then) 

Содержание KFOB-C

Страница 1: ...1 KFOB C Remote Control Manual 009204...

Страница 2: ...an own Z Wave network The connected new device actuator can be controlled using the two buttons left Button 1 up on open Button 3 down off closed After the first action you can further manage add rem...

Страница 3: ...usion process e g pushing local inclusion button three times o The KFOB can even control devices without a central controller and will become primary controller of an own Z Wave network The connected...

Страница 4: ...o a different controller The device can hand over its primary role to another controller and become secondary controller Turn into management mode by pressing all four buttons for 1 second The green L...

Страница 5: ...his mode also implements communication pattern 7 Switch All commands parameter 11 14 3 In this mode all neighboring devices will receive Switch All set On Off command and interpret it according to the...

Страница 6: ...clusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion res...

Страница 7: ...tain network operations to send out a Node Information Frame Pressing button 2 in management mode will issue a Node Information Frame LED Control 1 Confirmation Green 1 second 2 Failure Red 1 second 3...

Страница 8: ...0 Separately 1 In pair without double clicks default 2 In pair with double clicks Button 2 and 4 pair mode Parameter Number 2 Size 1 In separate mode button 2 works with control group B button 4 with...

Страница 9: ...l 4 Send scenes 5 Send preconfigured scenes 6 Control devices in proximity 7 Control door lock 8 Central scene to gateway default Send the following switch all commands Parameter Number 21 Size 1 Valu...

Страница 10: ...een a controlling device and a controlled device Wake up Notification is a special wireless message issued by a Z Wave device to announce that is able to communicate Node Information Frame is a specia...

Страница 11: ...the degree specified in the terms of sale and delivery The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written...

Отзывы: