15
3.11.
Additional information
Menu
Meaning
Software Version
MASTER: XX.XX.XX
Control board program
ID Code:
XXXXXXXX
Configuration code
S/N:
XXXX-XXXXXX-XXX
Serial number
MAC address:
XXXXXXXXXXXX
MAC address for Bluetooth connection
Int temperature:
XX°C
Internal temperature
3.12.
Safety
3.12.1.
Alarms and alerts
SAFETY
DEFAULT
CONFIGURATION
AUTOMATIC OPERATION(S)
UPON ACTIVATION
DISMISSAL*
Message
displayed
Immediate stop
of chlorine dosing
and/or pH regulation
Alarms
Activated
Alarm
(…)
Yes
Press the
OK
or button (press
or press and hold, depending on
whether it is an alarm or alert).
Alerts
Activated
Info
(…)
No
*
The corresponding alarm or alert is maintained while the detected fault remains in place, and the corresponding
message reappears a few moments after dismissal.
MESSAGE
DISPLAYED/FAULT
DETECTED
IMMEDIATE
AUTOMATIC STOP
POSSIBLE
CAUSE
CHECKS AND REMEDIES
OPTION TO
DISABLE VIA
THE ‘
Settings -
Alarms
’
menu
Chlorine
dosing
pH
regulation
Alarm
Empty CL container
Yes
No
Empty chlorine
container
Replace the chlorine container.
Yes
Alarm
Empty pH container
No
Yes
pH corrector
container empty
Replace the pH corrector container.
Yes
Alarm
Flow
Measurement
Yes
Yes
Insufficient
water flow in
the measuring
chamber
Check that:
-
the flow sensor is properly
connected to the electronics
unit.
-
the valves on the measuring
circuit are open.
-
the filter pump is working
properly.
-
the filtration circuit is not
blocked.
No