After setting, hold down the 

SET

 button 3 seconds or leave it with no 

operation 15 seconds, the system will save the parameter changes and 

return to the working mode. 

Note:

 

You can only set the basic Settings, leaving the advanced 

Settings unchanged, and only change the advanced Settings parameters 

if necessary. 

 

Advanced Setting Mode

: Press & hold down 

SET

 key 3 seconds to 

enter the advanced setting mode. You are able to set AL (Low Alarm 

Temperature point),  AH (High Alarm Temperature point), PT 

(Compressor 

Protection  Time),  CF  (℃/℉  Display  setting)  and  CA 

(Calibration  function) parameters. After settings, press & hold down 

SET

 key 3 seconds or leave it with no operation 15 seconds to save 

parameter changes and return to working mode. 

 

User Tips: 1)

Under setting mode, press 

SET

 key to cycle through all 

parameter codes, press 

”& “

” 

to adjust the setting values below.   

2)

Press & hold down 

” & “

” 

can adjust setting value more quickly. 

 

Cooling

 

Heating 

TL 

TS

 

TH

 

Содержание TC-15A

Страница 1: ...User Manual Model No TC 15A Thank you for purchasing the Temperature Controller by Poniie Please read this manual carefully before using this product ...

Страница 2: ... the metal NTC probe will be slowly damaged by salt water or acid alkali water 1 6 NOTE If the relays are used over capability contact fusing or burning may occur Please use the relays within their rated load 2 Overview What is TC 15A TC 15A is an easy to use safe and reliable dual relay output temperature controller It can be connected to both heating and cooling loads at the same time to control...

Страница 3: ...delay protection High and low temperature alarm Faulty sensor alarm 3 Specification Temperature Control Range 40 0 99 9 Temperature Resolution 0 1 Temperature Accuracy 1 0 20 0 70 0 Input Power 100 125V 50 60Hz Maximum Output Load 15A 100 125V 1650W 110V Buzzer Alarm Low and High Temperature Alarm Sensor Type NTC sensor Control Panel Cable Length 1 5m 4 9ft Input Power Cable Length 1 7m 5 6ft Sens...

Страница 4: ...for both heating and cooling It can be taken as the central temperature point in setting mode displays setting value of menu codes When controller working normally press key the setting Low Temperature TL point is displayed press key the setting High Temperature TH point is displayed The screen will auto return to normal display after 2 seconds 4 2 How to set parameters Basic Setting Mode Press SE...

Страница 5: ...conds to enter the advanced setting mode You are able to set AL Low Alarm Temperature point AH High Alarm Temperature point PT Compressor Protection Time CF Display setting and CA Calibration function parameters After settings press hold down SET key 3 seconds or leave it with no operation 15 seconds to save parameter changes and return to working mode User Tips 1 Under setting mode press SET key ...

Страница 6: ... Flow Chart Basic Setting Mode Advanced Setting Mode Short press SET Press hold SET for 3s SET 3S SET 3S TL SET 23 0 SET AL 20 0 SET AH 90 0 SET PT 2min CF CA 0 TS 25 0 TH 27 0 SET SET Working Normally SET SET ...

Страница 7: ...0 0 6 5 6 1 Temperature Control Range Setting TL TS TH This controller has a heating and cooling control outlets However you can only use the heating or cooling side for your project When measured temperature TL system enter heating state the heating outlet relay starts to work when it heats up to shutdown point TS the heating relay stops When measured temperature TH system enter cooling state the...

Страница 8: ...uzzer will alarm until temperature AL or any key is pressed When measured temperature AH high temperature alarm will be triggered buzzer will alarm until temperature AH or any key is pressed Note If you set the AL TL then the real low temperature alarm point is TL 0 5 If you set the AH TH the real high alarm point is TH 0 5 6 3 Compressor Protection Time PT Under cooling mode compressor protection...

Страница 9: ...ration function to align the measured temperature and actual temperature The corrected temperature equals to temperature before calibration plus corrected value corrected value can be positive 0 or negative value 7 Error Description 1 If LED displays flashing code AL or AH please kindly check your AL or AH setting in advanced setting mode Buzzer will alarm until temperature fall into setting range...